8.7.2 Target Weight Selection
1. From the weight display, briefly press and then release the Fn/ key.
2. The display will show the prompt id=.
3. Press the TARE key.
4. The display will show the ID of the currently selected target weight.
5. If the setting displayed is acceptable, press the TARE key to save it.
6. Otherwise, use the Fn/▲ key to enter a new value for the ID.
7. When the desired value is displayed, press the TARE key to save it.
8. The indicator will return to the weight display.
8.7.3 Checkweigher Operation
With the Checkweigher function enabled and activated, during operation
the indicator will compare the displayed weight with the preset values
and display the results as under, accept, or over.
When the displayed weight is less than the minimum acceptable weight,
the arrow over OUT1 < (the UNDER annunciator) will turn on and the
display will change to the color selected in section 4.15, Display
Backlight Color Setup.
When the displayed weight is greater than the maximum acceptable
weight, the arrow over OUT3 > (the OVER annunciator) will turn on
and the display will change to the color selected in section 4.15,
Display Backlight Color Setup.
When the displayed weight is within the range from minimum acceptable
weight to maximum acceptable weight, the arrow over OUT2 (the
ACCEPT annunciator) will turn on and the display will change to the
color selected in section 4.15, Display Backlight Color Setup.