Model 190 Installation, Technical and Operation
8400-M022-O1 Rev J
Page 122
Error
Cause (A.) and Corrective Action (B.)
notArE
The NET/GROSS key was pressed when there is
no stored tare.
oCAP
A. The load on the scale exceeds the capacity of
the scale.
B. Remove the excess load.
-oF-
A. The indicator is trying to display a positive
number with more than six digits or a negative
number with more than five digits.
B. Return to Gross weight mode and review the
Tare weight. Might indicate incorrect
calibration.
UnStb
A. Motion was present when a print was initiated.
B. Wait for a stable indication before printing.