Model 190 Installation, Technical and Operation
8400-M022-O1 Rev J
Page 29
SLEEP= (Sleep Mode Feature)
The Sleep Mode feature conserves battery power when the indicator
remains unused for a selected period of time. With the feature enabled,
the display will be blank.
Press the TARE key to show the current status of this feature. If a
number other than 0 is shown, this feature is selected and the number
shown corresponds to the number of minutes of a stable zero weight
reading before the indicator enters the sleep mode.
If the setting displayed is acceptable, press the TARE key again to
save it. Otherwise, use the Fn/ and UNITS/ keys to enter a new
setting (0 to 10) and then press the TARE key to store the new
setting.
NOTE: Selecting 0 disables this feature.
A oFF= (Auto Shutoff)
The Automatic Shutoff feature will automatically turn the indicator off
(when it is not in use) after a predetermined period of inactivity to prolong
battery life. To turn the indicator back on you must press the ON/OFF
key.
Press the TARE key to show the current status for this feature. A
number other than 0 indicates that the auto shutoff feature is enabled and
the displayed number corresponds to the number of minutes of stable
weight displayed before the indicator is turned off automatically.
If the setting displayed is acceptable, press the TARE key again to save
it. Otherwise, use the Fn/ and UNITS/ keys to enter a new setting (0
to 10) and then press the TARE key to store the new setting.
NOTE: Selecting 0 disables the Auto-Shutoff feature.