Model 190 Installation, Technical and Operation
8400-M022-O1 Rev J
Cont1= (Continuous Output on Serial Interface)
Press the TARE key to show the current setting. If the setting
displayed is acceptable, press the TARE key again to save it.
Otherwise, use the Fn/ key to toggle to a new setting and then
press the TARE key to save it.
YES = Continuous Output on Serial Interface
no = No Continuous Output on Serial Interface
If Cont1= YES (Continuous Output) is selected, an
additional prompt, tYPE= will be displayed.
If Cont1= no (No Continuous Output) is selected, proceed
to the Weight On Demand section. (See Paragraph 4.8.3)
tyPE= (Continuous Output Format)
Press the TARE key to show the current setting. If the setting
displayed is acceptable, press the TARE key again to save it.
Otherwise, use the Fn/ key to toggle to a new setting and then
press the TARE key to save it.
Allowable settings are:
0 = Continuous Output uses SMA format
1 = Continuous Output uses Cardinal Scoreboard format
4.8.1 SMA Continuous Output Format
If SMA is selected, data will be transmitted in the following format:
<lf><s><r><n><m><f><xxxxxx.xxx><uuu><cr>
Where:
Z= center of Zero, O = Overcap, E = zero
Error, e = weight not currently being displayed
G = Gross, T = Tare, N = Net
M = Motion, " "(blank) = no motion
Ten characters including decimal point (if any)