3.5 Digital Fill Control (DFC)
Specified Target Weight DFC
This feature is useful to determine if an item is above a specified target weight.
Recommended Settings:
D OUT= 4 (Required) or 14 (Required for inverted outputs)
FIL-AA= YES for each completed fill weight to be added to an accumulator
PURGE= N Where N the number of fill cycles you require before a manual feeder
purge will take place. Set to 0 to disable
P-WGT= This is the weight of material contained within the feeder you will be
purging.
SPEED= 1 (discharge motor only has 1 speed) or 2 (discharge motor is 2 speed)
GATE= This is the motor control or gate sequence if using 2 speed operation.
Refer to the setup portion of the manual for details on this setting)
A-TRIM= YES Automatically adjust trim weight for more accurate fill
A-PRNT= YES If using a printer, this will automatically print at the end of a fill cycle
DFC Preset Setup Procedure (Load & Unload Mode):
1. Verify your desired fill and trim weights are stored in the indicator by
pressing the PRESET key. If SPEED= 2 was selected above, skip to
step 3.
2. The display will read FILL= . This is the desired fill weight. Press the
ENTER key to display the current value. If this value is correct,
press the ENTER key to accept otherwise key in your desired fill
weight then press ENTER. Skip to step 5.
3. The display will read FAST= . This is the weight at which the indicator
will switch from fast to slow fill. Press ENTER to display the current
value. If this value is acceptable, press ENTER to accept otherwise
key in your desired fast fill then press ENTER.
4. Next you will be prompted SLOW= . This is the desired final fill weight.
Press ENTER to display the current value. If this value is
acceptable, press ENTER otherwise key in your desired fill weight
then press ENTER.