DFC Weighing Procedure (Unload Mode):
1. Verify the scale is in Load mode (the Unload annunciator will
be turned off). You can toggle back and forth between Load
and Unload mode by pressing the LOAD/UNLOAD key.
2. With the scale empty, verify the scale is showing 0 units Gross.
If not in Gross mode, press the 0 key then the TARE key to
clear the stored tare weight and the indicator will display Gross
weight.
3. Now Load the scale with the amount of material you wish to
distribute (this should be greater than or equal to your preset
fill weight).
4. Press the LOAD/UNLOAD key. The scale will store the filled
weight as the tare weight, switch to Unload mode, and display
0 units Net weight.
5. The scale is now ready to be Unloaded using the DFC.
Position the feeder over the container to be filled and start the
fill by press the F key followed by the ID/START key.
6. The fill will start and proceed according to the SPEED and GATE
settings you selected.
7. If at any time, you wish to pause the fill cycle, press the HOLD
key. The indicator will display PAUSED. To restart/continue the
filling operation, press the HOLD key again to “unpause.” Or
to abort the fill, press the key.
8. The fill cycle will end once the preset fill weight is removed
from the scale. If DFCEND=YES was selected, the indicator will
display DONE until a key is pressed.
9. If there is enough material remaining on the scale, position the
feeder above your next container to fill and press the F key
then the ID/START key to start the next fill cycle. (If the DONE
message is still displayed, simply press the ID/START key to
start the next fill). If there is not enough material on the scale
when these keys are pressed, the indicator will display ERROR.
Repeat this step for subsequent fill cycles.