212/212X Installation & Technical
8200-M639-O1 Rev D 09/14
Page 114
Box-Tracker DFC Mode (Box Fill)
In this mode, the 100 memory ID locations are used to keep track of a material’s
remaining Net weight. Each memory location also will contain a target fill weight,
a weight accumulator, and a fill counter. The indicator will prompt for all of these
values when storing/editing a memory ID file. Refer to section 3.6 for instruction
on storing/editing memory. This mode also will default to a 2-speed, chatter gate
operation (non-selectable) with no auto-trim.
Recommended Settings:
D OUT= 4 (Required) or 14 (Required for inverted outputs)
FMODE=2 (Required for Box Fill)
FIL-AA= YES for each completed fill weight to be added to an accumulator
PURGE= N Where N the number of fill cycles you require before a manual feeder
purge will take place. Set to 0 to disable
P-WGT= This is the weight of material contained within the feeder you will be
purging.
CHATR= This is the amount of time (in seconds) the output will be active when
chattering.
CHTOFF This is the amount of time (in seconds) the output will be inactive when
chattering.
TRMWT= This is the trim weight. Target weight – trim weight = weight at which
chattering will begin.
A-PRNT= YES If using a printer, this will automatically print at the end of a fill cycle
DFCEND YES If you want the indicator to display DONE upon completion of a fill
cycle.
DFC Preset Setup Procedure (Unload Mode Only):
1. Verify your desired fill weight is stored in the indicator by pressing the
PRESET key.
2. The display will read FILL=. This is the target fill weight. Press the
ENTER key to display the current value. If this value is correct, press
the ENTER key to accept otherwise key in your desired fill weight then
press ENTER.
3. Repeat these steps after loading a memory ID as the indicator will load
the memory ID’s target weight whenever an ID is selected.