212/212X Installation & Technical
8200-M639-O1 Rev D 09/14
Storing/Reviewing/Selecting/Editing Memory
Locations in Plot-Tracker DFC Mode:
This section describes the memory operations of the Plot-Tracker DFC
mode. This mode must be selected prior to performing any of the
following operations. To select, refer to the recommended settings above.
Refer to section 3.6 for additional instruction on reviewing/editing memory.
Storing a Box ID:
1. Press the MEM key. The indicator will prompt ID=.
2. Use the alphanumeric keys to name the box ID you are creating
and then press the ENTER key.
3. Next the indicator will prompt FILWT=. Press ENTER to display
the fill weight value associated with this ID and then enter your
desired target fill weight for this box ID and press the ENTER
key (a non-zero value is required).
4. The indicator will then prompt for the net weight of the box
(“NETWT=”). Press ENTER to display the current value, then
key in net weight of your box and press ENTER.
5. The indicator will then prompt for the starting weight
accumulation (“ACCUM=”) and fill counter (“COUNT=”). You
can set these values just like steps 3 and 4 or simply press
ENTER to store the default value of 0 for each. After storing the
fill counter value, the indicator will return to the weight display
(you can tell this whenever the MEM display annunciator turns
off).
Storing a Plot ID:
1. Press the MEM key. The indicator will prompt ID=.
2. Use the alphanumeric keys to name the box ID you are creating
and then press the ENTER key.
3. Next the indicator will prompt FILWT=. Press ENTER to display
the default fill weight value of 0. Verify the displayed value is
equal to 0 and then press ENTER. If the displayed value is not
zero, press the 0 key and then press ENTER.
4. The indicator will then prompt for the starting weight
accumulation ACCUM=. Press ENTER to display the default
starting value. If you wish to modify the starting accumulation,
enter your desired starting value and then press ENTER.