212/212X Installation & Technical
8200-M639-O1 Rev D 09/14
Page 15
Key
Description
Pressing the F key will display “ F--”. All other keys will
be disabled except:
0/NO. This key sequence is used to enter the Setup
and Configuration mode. While in Setup and
Configuration, pressing the F key will step to the
beginning of each setup section.
RECALL: This key sequence initiates the accumulator
statistics (A-STAT) menu.
CLEAR: Exits this display and returns to displaying
weight if an ID is not selected. If an ID is selected,
the user will be prompted to confirm an ID erase.
3: This key sequence is used to set the Date and Time.
8: This key sequence is used to change units.
: Exits this display and returns to displaying weight.
START: Used for starting a Digital Fill Control cycle.
PRINT: If an ID is selected, the stored ID information
will be printed. If an ID is not selected, the indicator
will perform a print using the print tab settings.
Pressing the (asterisk) key after an ID has been
selected will exit “ID Mode.” The ID and MEM
annunciators will blink twice to signify this.
If an ID has not been selected the indicator will display
FUNCT=”.
Pressing the F key after the key will enter the Setup
Review mode where some of the indicator Setup and
Configuration parameters can be changed.
The ENTER key serves two purposes. First, when
reviewing setup parameters, pressing the ENTER key
will display the current setting of the parameter.
Second, the ENTER key is used to signal completion of
the entry of data and causes the indicator to process
the data entered.