212/212X Installation & Technical
8200-M639-O1 Rev D 09/14
Page 42
CAP= (Capacity)
1. Press the ENTER key to show the current setting.
2. If the setting displayed is acceptable, press the ENTER key
again to save it and advance to the CAL ? prompt.
3. Otherwise, use the numeric keys to enter a new setting
(allowable settings are: 1 through 999,999) and then press the
ENTER key to save it.
4. The display will change to the CAL ? prompt.
Cal ? (Calibrate)
1. With CAL ? displayed, press the ENTER key. The display will
change to show the current setting NO.
2. To save the new Quick Calibration settings and calibrate
the
scale, press the 1/YES key and then press the ENTER key.
3. Starting at the left and proceeding right, a series of dashes will
appear on the display.
4. Next, starting at the left and proceeding right, the dashes will
disappear, after which the display will change to the weight
display mode.
5. To skip calibrating the scale and exit Quick Calibration, press
the ENTER key to select NO.
6. The display will return to the weight display mode.
IMPORTANT! If NO is selected for the CAL ? prompt,
(skipping calibration and exiting Quick Calibration)
it should be noted that the new quick calibration
settings selected WILL NOT BE SAVED!
The empty scale weight is established in order to determine
when the scale is over capacity. If calibrating with weight on the
scale is necessary, we recommend that you later calibrate again
once the scale is empty in order to establish a correct empty
scale weight.