212/212X Installation & Technical
8200-M639-O1 Rev D 09/14
Page 47
Settings
SETUP
USA= (Domestic or International)
With SEtUP displayed, press the ENTER key. The display will change to
USA=. Press the ENTER key to show the current setting. If the setting
displayed is acceptable, press the ENTER key again to save it.
Otherwise, using the numeric keys, 0/NO or 1/YES, enter the new setting
and then press the ENTER key to save it.
Yes (Domestic)
no (International)
Date= mm/dd/yy
Date= dd/mm/yy
Trl= no
Trl= yes
Cap + 4% to OC
Cap + 9 grads to OC
PT printed with tare
Lamp test on power up
Unit1= (Weighing Unit 1)
Press the ENTER key to show the current setting. If the setting
displayed is acceptable, press the ENTER key again to save it.
Otherwise, use the numeric keys to enter a new setting and then press
the ENTER key to save it. Allowable settings are 0 to 6.
0 = none
1= tn (tons)
2= g (grams)
3 = lb (pounds)
4 = oz (ounces)
5 = kg (kilograms)
6 = tonnes (metric tons)
int= (Interval Setting)
Press the ENTER key to show the current setting. If the setting displayed
is acceptable, press the ENTER key again to save it. Otherwise, use the
numeric keys to enter a new setting and then press the ENTER key to
save it. Allowable settings are: 1 through 99.