212/212X Installation & Technical
8200-M639-O1 Rev D 09/14
Page 50
d oUt= X,Y (Digital Output)
Press the ENTER key to show the current setting. If the setting
displayed is acceptable, press the ENTER key again to save it.
Otherwise, use the numeric keys to enter the X, Y settings for the
Digital Output, and then press the ENTER key to save it.
where:
X = State below cutoff
(0=Output connected to common, 1=Output not connected to
common)
Y = Preset Number or Digital Fill Control Mode
0 =
Digital Output is disabled
Preset Weigh Comparator Feature
1 =
Low State before cutoff with 1 active Preset
2 =
Low State before cutoff with 2 active Presets
3 =
Low State before cutoff with 3 active Presets
11 =
High state before cutoff with 1 active Preset
12 =
High state before cutoff with 2 active Presets
13 =
High state before cutoff with 3 active Presets
Digital Fill Control Feature

4 =
Low State before cutoff on Digital Fill Control Mode
14 =
High state before cutoff on Digital Fill Control Mode
If 1, 2, 3, 11, 12 or 13 is selected for d oUt=, proceed to the
setup prompt A-HLD= to continue setup.

If 4 or 14 is selected for d oUt=, proceed to the setup prompt
FIL-aa to continue setup.