212/212X Installation & Technical
8200-M639-O1 Rev D 09/14
GATE= (Gate Sequence)
NOTE: This selection requires two speed operation (SPEED=2).
Press the ENTER key to show the current setting. If the setting
displayed is acceptable, press the ENTER key again to save it
and proceed to the setup prompt is A-TRIM. Otherwise, using the
numeric keys, enter the new setting and then press the ENTER
key to save it. Allowable settings are 1, 2, or 3.
GATE= 1 (AB->B)
The AB->B selection will begin the operation with both outputs
on until the weight reaches the FAST= value. At that weight, the
“A” (fast) output will be turned off. The “B” (slow) output will
remain on until the SLOW= (final preset wt.) weight is reached.
At that weight, the “B” (slow) output will be turned off.
GATE= 2 (A->B)
With A->B selected, the operation will begin with only the “A”
(fast) output on until the weight reaches the FAST= value. At
that weight, the “A” (fast) output will be turned off and the “B”
(slow) output will be turned on. The “B” (slow) output will
remain on until the SLOW= (final preset wt.) weight is reached.
At that weight, the “B” (slow) output will be turned off.
GATE= 3 (CHTR, Chatter)
The Chatter Gate selection and will control one relay. It begins
the operation with the “A” (fast) output on until the weight
reaches the FAST= value. At that weight, the “A” (fast) output
will be turned off. The “A” (now as slow) output will then be
turned on for a preset time (CHATTER=, 0 to 99.9 seconds, set at
the DFC PRESET PARAMETERS MENU). The “A” (slow)
output will be turned off and the weight value will be compared
to the SLOW= (final preset wt.) value less the TRIM= value. This
will be repeated until the weight is equal to or greater than the
SLOW= (final preset wt.) value less the TRIM= value.