212/212X Installation & Technical
8200-M639-O1 Rev D 09/14
Page 56
CLtAr= (Clear Tare)
The Clear Tare feature allows the indicator to clear the Stored
Tare weight when the Net weight goes below a value greater than
1/2 the stored tare weight or goes below zero (a negative net
weight after display of a positive net weight). With this feature
enabled, the operator must re-set the tare after completion of a
transaction when the load (container plus item) is removed from
the scale.
Press the ENTER key to show the current setting. If the setting
displayed is acceptable, press the ENTER key again to save it.
Otherwise, using the numeric keys, 0/NO or 1/YES, enter the new
setting and then press the ENTER key to save it.
CLtAr= YES
CLtAr= NO
Automatically clears Stored
Tare when Net weight goes
below zero
Stored Tare is not cleared
when Net weight goes
below zero
The following is a typical example of the Clear Tare feature in use.
1. Place container on scale, then press TARE key (with diamond
“T” symbol).
2. Load container with item to be weighed and perform normal
weighing operation.
3. Remove load (item AND container) from scale.
4. Scale weight returns to below zero (weight of container) and is
then reset to zero.
5. Operator is required to repeat step 1 before next weighing
operation.