212/212X Installation & Technical
8200-M639-O1 Rev D 09/14
Page 84
tyPE= (Continuous Output Format)
Press the ENTER key to show the current setting. If the setting
displayed is acceptable, press the ENTER key again to save it.
Otherwise, using the numeric keys enter the new setting and then
press the ENTER key to save it. Allowable settings are .0, 1 or 2.
0 = SMA
1 = Cardinal Scoreboard
2 = SB-500
NOTE: See Continuous Output Serial Port 1, tyPE= for description
of output formats.
LrP= (Local/Remote Port)
NOTE: This prompt will ONLY be displayed if SERSCL is set to
YES in the A-D section.
Press the ENTER key to show the current setting. If the setting
displayed is acceptable, press the ENTER key again to save it.
Otherwise, using the numeric keys enter the new setting and then
press the ENTER key to save it. Allowable settings are 1 or 3
1 =
Indicator Port 1
3 =
Port on optional 2XX-RS232 card (if installed)