8200-M698-O1 Rev B 225 Installation and Technical
98
ID STORAGE OPERATION, CONT.
Gross Weight Alarm
If WT ALARM = YES was selected in the ID Storage Menu setup, the indicator will display
and activate a PRESET soft key. By using the PRESET key, a gross weight can be
programmed to turn on the PWC1 control output for a programmed time (1-99 seconds) when
the gross weight exceeds the programmed weight.
ALARM WT(PWC 1)=XXXXXX
To program the alarm gross weight and alarm on time, press the PRESET key. The
display will show ALARM WT(PWC 1)=XXXXXX. Using the numeric keys, enter the
desired alarm gross weight and press the ENTER key. The preset weight will be stored
and the display will change to show the alarm TIME ON=X parameter.
IMPORTANT! The gross weight must fall below 1/2 the preset weight
before the alarm is re-armed.
TIME ON=X
Using the numeric keys, enter the desired alarm TIME ON=X value (1-99 seconds) and
press the ENTER key. The on time will be stored and the display will return to normal
mode. Note that setting TIME ON=0 disables the alarm.