8200-M698-O1 Rev B 225 Installation and Technical
111
PRESET WEIGHT COMPARATORS OPERATION
17. SET TRIM (SET TRIM WEIGHT)
1. With the display showing the values of the enabled PWCs, press the 1 and 7 keys and
then the ENTER key.
1.T= 0 7.T= 0 13.T= 0
2.T= 0 8.T= 0 14.T= 0
3.T= 0 9.T= 0 15.T= 0
4.T= 0 10.T= 0 16.T= 0
5.T= 0 11.T= 0 17. SET WGT
6.T=
0 12.T= 0 18. SET SCALE
ENTER
PWC# TO CHANGE: 0
PRESET TRIM SCALE EXIT
2. The display will change to show the values of the enabled PWCs preset trim weights.
Note that 0 is the factory default value for each preset.
3. If the values displayed for each preset trim weight are acceptable, press the ENTER key
to exit and return to normal operation.
4. Otherwise, use the numeric key to select the PWC# (1 to 16) trim weight to change and
then press the ENTER key. The display will change to show the current trim weight
value (TRM #= X) of the preset selected.
5. Using the numeric keys, enter the new value for the preset trim weight and then press
the ENTER key to save the new setting.
6. Continue with this procedure until a value for each preset trim weight to be used has
been entered.
7. After the last preset trim value has been entered, press the 1 and 8 keys and then the
ENTER key to enter the preset scale values or press the ENTER key to exit and return
to normal operation.
Remember that the trim weight is to compensate for material in transit and
causes the preset to turn on when the displayed weight equals or exceeds the
Preset weight value LESS its associated Trim weight value. Also, remember
that the preset is based on the displayed weight, which can be either gross or
net weight.