8200-M698-O1 Rev B 225 Installation and Technical
134
ELECTRONIC TALLEY ROLL (ETR) FILE, CONT.
Recording a Electronic Tally Roll Transaction Record
To record an ETR transaction record, the computing peripheral (host device) transmits the
SMA XT command (also called TALLEY ON STABLE) to the weight indicator.
Electronic Talley Roll (ETR) Format
The host device (computing peripheral) sends:
<0Ah><XT><ODh>
The 225 weight indicator will respond by transmitting the following to the host device:
<s><xxxxxx><d><uu><m><cc>#nnnnnn<cr>
Where:
s = Sign "-" = negative, " " (blank) = positive
xxxxxx = Weight Six digits
d = Decimal point Added to string if enabled in setup
uu = Units tn, lb, l/o, oz, t, kg, g
m = Mode G = Gross, N = Net
cc = Weight Status OC = over capacity
BZ = below zero
MO = motion
ee = weight not currently being displayed
#nnnnnn Consecutive Number
cr = Carriage Return (hex 0D)
NOTE: The weight and consecutive number data is only stored in the indicator’s
non-volatile memory and transmitted to the host device when the weight is stable
(no motion).