8200-M698-O1 Rev B 225 Installation and Technical
45
CALIBRATION AND SETUP, CONT.
With the indicator ON, press the SHIFT key and then press the Navigation ENTER key (red
square key in center of the Navigation arrows). The display will change to show the
SETUP/REVIEW MENU.
SETUP/REVIEW MENU
1.ENTER CALIBRATION AND SETUP
2.VIEW AUDIT TRAIL COUNTERS
3.CALIBRATE SCALE 1
8.SCALE ID=00
9.DEL CUSTOM TICKET
10.PRINT SETUP
Enter Selection: 1 ^ EXIT
1. ENTER CALIBRATION AND SETUP
SETUP MENU #1
With the SETUP/REVIEW MENU displayed, press the 1 key and then the ENTER key. The
display will change to show SETUP MENU #1.
SETUP MENU #1
1. USA=XXX 6. CLR TARE=XXX
2. NSC=XXX 7. CLEAR ID=XXX
3. LFT=XXX 8. NO OF SCALES=X
4. N/A 9. TOTALIZE=XXX
5. TIME=XX 10. MODE OF OP=0 NORM
Enter Selection: 0 ` NEXT ^ EXIT
1. USA=XXX (DOMESTIC or INTERNATIONAL)
With SETUP MENU #1 displayed the current setting for the USA= parameter will be shown.
Note that XXX is the current value. If the setting displayed is acceptable, proceed to the
next setup parameter.
Otherwise, press the 1 key, the ENTER key, YES or NO (on the soft keys) and then the
ENTER key to save the new setting and return to SETUP MENU #1.
USA=YES (Domestic) USA=NO (International)
DATE = MM/DD/YY DATE = DD/MM/YY
Z LIMIT = NO Z LIMIT = YES
CAP + 5% to OC CAP + 9 grads to OC
ETR able = YES
PT printed with tare. Lamp test on
power up. Lorry Weigher Operation
(Any MODE OF OP but 1 or 6).
NSC (Australia NSC Requirements)
setup parameter selection allowed