8200-M698-O1 Rev B 225 Installation and Technical
49
CALIBRATION AND SETUP, CONT.
10. MODE OF OP=X XXXX (MODE OF OPERATION)
With SETUP MENU #1 displayed the current setting for the MODE OF OP= parameter will
be shown. Note that X is the current value and XXXX is the mode of operation abbreviation.
If the setting displayed is acceptable, press NEXT (Navigation Keys Down Arrow) to
proceed to SETUP MENU #2 or press EXIT (Navigation Keys UP Arrow) to return to the
SETUP/REVIEW MENU.
Otherwise, press the 1 and 0 keys and then the ENTER key. The display will change to
show the Mode Of Operation Menu.
0. Normal Indicator (Normal Indicator = NORM)
Press the 0 key, the ENTER key and then press EXIT (Navigation Keys UP Arrow) to
exit and return to SETUP MENU #1. Press NEXT (Navigation Keys Down Arrow) to
proceed to the next display, SETUP MENU #2.
1. ID Storage (ID Storage = IDS)
Press the 1 key and then the ENTER key to proceed to the ID Storage Menu. Refer to
the ID STORAGE SETUP, Mode Of Operation = 1 (ID Storage) section of this manual.
2. Digital Fill Ctrl (Digital Fill Control = DFC)
Press the 2 key and then the ENTER key to proceed to the Digital Fill Control Menu.
Refer to the 225 Digital Fill Control manual.
3. Preset Weight Comp (Preset Weight Comp = PWC)
Press the 3 key and then the ENTER key to proceed to the Preset Weight Comparator
Menu. Refer to the PRESET WEIGHT COMPARATORS SETUP, Mode Of Operation = 3
(Preset Weight Comp) section of this manual.
4. Check Weigher (Check Weigher = CHW)
Press the 4 key and then the ENTER key to proceed to the Check Weigher Menu. Refer
to the 225 Check Weigher manual.
5. Batcher (Batcher = BATR)
Press the 5 key and then the ENT
ER key to proceed to the Batcher Menu. Refer to the
225 Batcher manual.
6. Package Weigher (Package Weigher = PKW)
Press the 6 key and then the ENTER key to proceed to the Package Weigher Menu.
Refer to the 225 Package Weigher manual.