8200-M698-O1 Rev B 225 Installation and Technical
60
CALIBRATION AND SETUP, CONT.
DIO SETUP (PWC Status)
IMPORTANT! The DIO SETUP (PWC Status) cannot be selected if Mode of
Operation = 0, Normal Indicator is enabled.
With the SETUP MENU #1 displayed, press NEXT (Navigation Keys Down Arrow) to
proceed to SETUP MENU #2.
SETUP MENU #2
1. SERIAL
2. DIO
3. PRINT TABS
4. SETUP SCALE 1
5. CALIBRATE 1
Enter Selection: 0 ` NEXT ^ PREV
2. DIO (TOGGLE PWC STATUS)
With the SETUP MENU #2 displayed, press the 2 key and then the ENTER key to proceed
to the DIO SETUP MENU.
DIO SETUP MENU
PWC1-OFF PWC6-OFF PWC11-OFF PWC16-OFF
PWC2-OFF PWC7-OFF PWC12-OFF 17. ALL OFF
PWC3-OFF PWC8-OFF PWC13-OFF 18. ALL ON
PWC4-OFF PWC9-OFF PWC14-OFF
PWC5-OFF PWC10-OFF PWC15-OFF
Enter PWC # to Toggle: 0 ^ EXIT
With the DIO SETUP MENU displayed, the current “state before cutoff” status of the 16
Preset Weight Comparators (PWC) will be shown. If the status displayed is acceptable,
press EXIT (Navigation Keys UP Arrow) to exit and return to the SETUP MENU #2.
Otherwise, press the PWC number, 17 or 18 to toggle the status (turn ON, relay closed
or OFF, relay open) and then press the ENTER key to save the new setting.
IMPORTANT! When power to the indicator is lost, the output goes to the OFF state.

Table of Contents