8200-M698-O1 Rev B 225 Installation and Technical
63
CALIBRATION AND SETUP, CONT.
2. PRT BEG=XXXXXXXXXXXX (PRINT BEGINNING)
With PRINT TABBING MENU #1 displayed the current setting for the PRT BEG=
parameter will be shown. Note that XXXXXXXXXXXX is the string of HEX numbers
1
sent to the printer before anything else. If the setting displayed is acceptable, proceed
to the next setup parameter.
Otherwise, press the 2 key, the ENTER key and then using the alphanumeric keys,
enter the new string and then press the ENTER key to save the new setting and return
to PRINT TABBING MENU #1.
3. AUTO LF=XXX (AUTOMATIC LINE FEED “DATA FORMAT TERMINATION”)
With PRINT TABBING MENU #1 displayed the current setting for the AUTO LF=
parameter will be shown. Note that XXX is the current value. If the setting displayed is
acceptable, proceed to the next setup parameter.
Otherwise, press the 3 key, the ENTER key, YES or NO (on the soft keys) and then the
ENTER key to save the new setting and return to PRINT TABBING MENU #1.
4. ENDING LF=XX (NUMBER OF LINEFEEDS PRINTED AFTER LAST LINE)
With PRINT TABBING MENU #1 displayed the current setting for the ENDING LF=
parameter will be shown. Note that XX is a pre-selected number of linefeed commands
that the indicator can transmit at the end of a data transmission to a printer, to space the
paper in the printer to the desired position for withdrawal or for the next print. If the
setting displayed is acceptable, proceed to the next setup parameter.
Otherwise, press the 4 key, the ENTER key and then using the numeric keys, enter the
value for the number of linefeeds to be executed after the last printed line and then
press the ENTER key to save the new setting and return to PRINT TABBING MENU #1.
Allowable values are 0 through 99.
5. PRT END=XXXXXXXXXXXX (PRINT BEGINNING)
With PRINT TABBING MENU #1 displayed the current setting for the PRT END=
parameter will be shown. Note that XXXXXXXXXXXX is the string of HEX numbers
1
sent to the printer after the ENDING LF. If the setting displayed is acceptable, proceed
to the next setup parameter.
Otherwise, press the 5 key, the ENTER key and then using the alphanumeric keys,
enter the new string and then press the ENTER key to save the new setting and return
to PRINT TABBING MENU #1.
1
HEX numbers are always 2 digits. For example, 7 is entered as 07. The maximum
entry is 6 numbers (12 characters). Valid entries are 01 through FF. Note that 00 is not
valid.