EasyManua.ls Logo

Carel gaSteam UG045 - Menu E. Settings - H. Supervision

Carel gaSteam UG045
120 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
ENG
7.8.6 Software update from USB pen drive
The update package can be downloaded from ksa.carel.com. The unit’s software can be updated using a
USB pen drive plugged directly into the c.pHC controller. In the pen drive’s root directory, create an
UPGRADE directory and copy the software update file to this directory. Once having plugged the pen
drive into the controller, go to screen Eg07 and set the Update unit software” parameter to YES.
Index Parameter Description
Eg07 Software update
Start software update from USB pen drive
Default: No
The steps to update the SW/OS (software/operating system) are:
l Save user parameters;
l SW/OS upgrade;
l Restore default parameter values;
l Write user parameters.
Once the update is complete, remove the USB pen drive from the controller.
After updating, the main user parameters do not need to be configured as the update automatically
restores them.
7.8.7 Export parameters to USB pen drive
The unit’s parameter configurations can be exported to USB pen drive, and subsequently loaded onto a
second unit, making installation and setup even faster. To save the parameters, plug the USB pen drive
into the c.pHC and then go to screen Eg08 and set the Export? parameter to YES.
Index Parameter Description
Eg08 Export parameters
Start exporting configuration from unit to USBpen drive
Default: No
The exported file will automatically be saved in the pen drive’s root directory and will be called:
UG4cgg.txt”
7.8.8 Import parameters onto the unit
The unit’s parameter configurations can be imported from a USB pen drive. To import the parameters,
make sure that the exported file is in the pen drive’s root directory and is called: UG4cgg.txt”. Then plug
the USB pen drive into the c.pHC and go to screen Eg09, and set the Import? parameter to YES.
Index Parameter Description
Eg09 Import parameters
Start importing configuration from USB pen drive to unit
Default: No
7.9
Menu E. Settings
- h. Supervision
7.9.1 Supervisor network address setting (Installer menu)
Supervision can be enabled on the Ethernet network or BMS serial port. The following protocols are
available to be set by the user:
Port Protocol
BMS Carel, ModBus, BACnet
Ethernet ModBus, BACnet
On screen Eh01, the port and supervisor protocol can be set, as well as the unit’s supervision address for
the BMS port.
80|7. User menu and unit configuration
gaSteam - UG +0300090EN rel. 1.2 09.10.2018