12
MAINTENANCE
If system chemical disinfection is practiced, chlorine can be used (calculated chlorine
concentration of mg/l maximum in water per one hour dwell time) at service interval
frequency.
FILTER CLEANING INSTRUCTIONS
These models are provided with a stainless steel lter preventing foreign particles to enter the lines. It is
recommended to clean the lter every six (6) month. If the water flow has decreased, this may be because the
lter is clogged. The lter can be cleaned as follows:
. a. Shut-o the water shut o valve.
b. Disconnect the water supply pipe from the adaptor and disassemble the lter.
c. Wash the lter under running water.
d. Reassemble the parts.
e. Restore the incoming water supply and make sure that there is no water leakage.
SOLENOID VALVE SERVICING
The solenoid valve diaphragm requires periodical cleaning every six (6) month.
Remove the diaphragm from the solenoid valve and examine it for dirt. in case it is dirty or clogged, wash it under
running water and reassemble it.
Do not attempt to dismantle the solenoid valve if you are unfamiliar with electronic solenoid valves.
CARE AND CLEANING OF CHROME AND SPECIAL FINISHES
DO NOT use steel wool or cleansing agents containing alcohol, acid, abrasives, or the like. Use of any prohibited
cleaning or maintenance products or substances could damage the surface of the outlet. For surface cleaning of
outlet us ONLY soap and water, then wipe dry with clean cloth or towel. When cleaning bathroom tile, the outlets
should be protected from any splattering of harsh cleansers.