All local and national code requirements governing installation of
oil burning equipment, wiring, and flue connections must be
followed. Some of the codes (issued by the Canadian Standards
Association, the National Fire Protection Agency, and/or the
American National Standards Institute) that may be applicable are:
ANSI/NFPA 31: INSTALLATION OF OIL BURNING EQUIP-
MENT
ANSI/NFPA 211: CHIMNEYS, FIREPLACES, VENTS, AND
SOLID FUEL BURNING APPLIANCES
ANSI/NFPA 90B: WARM AIR HEATING AND AIR CONDI-
TIONING SYSTEMS
ANSI/NFPA 70: NATIONAL ELECTRIC CODE
CSA B139: INSTALLATION CODE FOR OIL BURNING
EQUIPMENT
CAS C22.1: CANADIAN ELECTRICAL CODE
Only the latest issues of these codes should be used, and are
available from either: The National Fire Protection Agency,
Batterymarch Park, Quincy, MA 02269, or The Canadian Stan-
dards Association, 178 Rexdale Blvd., Rexdale, Ontario M9W1R3
Recognize safety information. This is the safety-alert symbol
.
When you see this symbol on the furnace and in instructions or
manuals, be alert to the potential for personal injury.
Understand the signal words DANGER, WARNING, and CAU-
TION. These words are used with the safety-alert symbol. DAN-
GER identifies the most serious hazards which will result in severe
personal injury or death. WARNING signifies a hazard which
could result in personal injury or death. CAUTION is used to
identify unsafe practices which may result in minor personal
injury or product and property damage. NOTE is used to highlight
suggestions which will result in enhanced installation, reliability or
operation.
INTRODUCTION
The model 58VMR Furnace is available in two sizes. Each size
unit is capable of 3 heat/airflow combinations by a simple nozzle
change. Unit 105-12 covers inputs of 70,000, 91,000, and 105,000
Btu, and unit 120-20 covers inputs of 119,000, 140,000, and
154,000 Btuh.
This furnace is a multipoise unit. It may be installed in the upflow,
downflow, or horizontal configuration.
The furnace is shipped in the upflow configuration, complete with
burner and controls. It requires a line voltage (115 vac) connection
to control box, a thermostat hook-up as shown on wiring diagram,
oil line connection(s), adequate duct work, and connection to a
properly sized vent.
Fig. 2—Dimensional Drawing
DIMENSIONS (IN.)
UNIT SIZE ABCDEFGHJKL
105–12 35 48-3/4 30-1/4 16-5/8 20 22 12 14 5 1-1/2 1-3/4
120–20 39-1/2 53 32-1/4 18-3/4 24 28 12-9/32 16 6 1-5/8 1-1/2
A98037
3
19
20
20
19
2
PULL
OIL INLET
(BOTH SIDES)
VENT CONN
ELECTRICAL
CONNECTIONS
(BOTH SIDES)
.88 DIAM TYP
KNOCK-OUT BOTH SIDES
FOR J DIAM VENT
TOP KNOCK-OUT
FOR J DIAM VENT
A
E
G
B
L
H
C
D
F
K
2