8.4.2 - Selection table of minimum and maximum wire sections - 400 V-3 ph-50 Hz
 

  

 
 1 x 50 XLPECu 160 1 x 120 XLPEAl 205
 1 x 50 XLPECu 160 1 x 120 XLPEAl 205
100 1x70 XLPECu 170 1 x 150 XLPEAl 210
110 1x70 XLPECu 170 1 x 185 XLPEAl 220
120 1x95 XLPECu 180 1 x 185 XLPEAl 220
130 1x95 XLPECu 180 1 x 240 XLPEAl 225
140 1 x 120 XLPECu 185 2x95 XLPEAl 195
155 1 x 120 XLPECu 185 2 x 120 XLPEAl 205
175 1 x 150 XLPECu 190 2 x 120 XLPEAl 205
 1 x 185 XLPECu 190 2 x 150 XLPEAl 210
 1x95 XLPECu 180 1 x 185 XLPEAl 220
1 x 120 XLPECu 225
 1x95 XLPECu 180 1 x 240 XLPEAl 225
1 x 150 XLPECu 230
 1 x 120 XLPECu 185 2 x 150 XLPEAl 265
1 x 240 XLPECu 235
 1 x 150 XLPECu 190 2 x 185 XLPEAl 270
2 x 120 XLPECu 280
 1 x 120 XLPECu 185 2 x 120 XLPEAl 255
2x95 XLPECu 270
 1 x 120 XLPECu 185 2 x 150 XLPEAl 265
2x95 XLPECu 270
 1 x 150 XLPECu 190 2 x 185 XLPEAl 270
2 x 120 XLPECu 280
 1 x 50 XLPECu 160 1 x 120 XLPEAl 205
1x70 XLPECu 205
 1x70 XLPECu 170 1 x 150 XLPEAl 210
1x95 XLPECu 215
 1x95 XLPECu 180 1 x 150 XLPEAl 210
1x95 XLPECu 215
 1x95 XLPECu 180 1 x 185 XLPEAl 220
1 x 120 XLPECu 225
 1 x 185 XLPECu 190 2 x 185 XLPEAl 270
1 x 240 XLPECu 235
 1 x 185 XLPECu 190 2 x 185 XLPEAl 270
2 x 120 XLPECu 280
 1 x 240 XLPECu 190 2 x 240 XLPEAl 280
2 x 150 XLPECu 290
* Powersupplywiresection(seediagrams/legendSinchapter‘Electricalconnection’).Thedisconnectswitchesareindicatedbya1.
8.4.3 - Selection table of minimum and maximum wire sections 400V-3ph-50Hz + option 150
 

  

 
 1x70 XLPECu 170 1 x 150 XLPEAl 210
 1x70 XLPECu 170 1 x 185 XLPEAl 220
 1x95 XLPECu 180 1 x 240 XLPEAl 225
 1x95 XLPECu 180 1 x 240 XLPEAl 225
 1 x 120 XLPECu 185 2x95 XLPEAl 195
 1 x 120 XLPECu 185 2 x 120 XLPEAl 205
 1 x 150 XLPECu 190 2 x 120 XLPEAl 205
 1 x 185 XLPECu 190 2 x 150 XLPEAl 210
 1 x 185 XLPECu 190 2 x 150 XLPEAl 210
 2x95 XLPECu 170 2 x 240 XLPEAl 225
 1 x 120 XLPECu 185 2 x 150 XLPEAl 265
1 x 185 XLPECu 235
 1 x 150 XLPECu 190 2 x 150 XLPEAl 265
1 x 240 XLPECu 235
 1 x 185 XLPECu 190 2 x 240 XLPEAl 280
2 x 150 XLPECu 290
 1 x 240 XLPECu 190 2 x 240 XLPECu 295
 1 x 150 XLPECu 190 2 x 185 XLPEAl 270
2 x 120 XLPECu 280
 1 x 185 XLPECu 190 2 x 240 XLPEAl 280
2 x 150 XLPECu 290
 1 x 240 XLPECu 190 2 x 240 XLPECu 295
 1x70 XLPECu 170 1 x 150 XLPEAl 210
1x95 XLPECu 215
 1x70 XLPECu 170 1 x 185 XLPEAl 220
1 x 120 XLPECu 225
 1x70 XLPECu 170 1 x 185 XLPEAl 220
1 x 120 XLPECu 225
 1 x 120 XLPECu 185 2 x 150 XLPEAl 265
1 x 185 XLPECu 235
 1 x 185 XLPECu 190 2 x 240 XLPEAl 280
2 x 150 XLPECu 290
 1 x 240 XLPECu 190 2 x 240 XLPEAl 280
2 x 150 XLPECu 290
 2x95 XLPECu 170 2 x 240 XLPECu 295
* Powersupplywiresection(seediagrams/legendSinchapter‘Electricalconnection’).Thedisconnectswitchesareindicatedbya1.