048-30
CC5A/CD5AW060 47,000 TDR 12.00 10.40 48,000 3.26 32,200 2.46 8.0
CE3AA060 47,000 TDR 12.00 10.40 48,000 3.60 32,400 2.62 8.0
COILS + 58MVP100-20 VARIABLE-SPEED FURNACE
CC5A/CD5AA060 46,000 TDR 11.50 10.05 48,000 3.46 32,200 2.54 8.0
CC5A/CD5AW060 47,000 TDR 12.00 10.40 48,000 3.26 32,200 2.46 8.0
CE3AA060 47,000 TDR 12.00 10.40 48,000 3.44 32,200 2.56 8.0
CK3BA060 47,000 TDR 12.50 10.80 48,000 3.68 31,800 2.66 8.0
CK5A/CK5BA060 47,000 TDR 12.50 10.80 48,000 3.46 32,200 2.54 8.0
CK5A/CK5BT060 47,000 TDR 12.50 10.80 48,000 3.68 31,800 2.66 8.0
CK5A/CK5BX060 47,000 TDR 12.00 10.55 48,000 3.68 31,800 2.66 8.0
COILS + 58MVP120-20 VARIABLE-SPEED FURNACE
CC5A/CD5AA060 46,000 TDR 11.50 10.05 48,000 3.46 32,200 2.54 8.0
CC5A/CD5AW060 47,000 TDR 12.00 10.40 48,000 3.26 32,200 2.46 8.0
CE3AA060 47,000 TDR 12.00 10.40 48,000 3.44 32,200 2.56 8.0
CK3BA060 47,000 TDR 12.00 10.35 48,000 3.58 32,400 2.60 8.0
CK5A/CK5BA060 47,000 TDR 12.00 10.35 48,000 3.58 32,400 2.60 8.0
CK5A/CK5BT060 47,000 TDR 12.00 10.35 48,000 3.58 32,400 2.60 8.0
CK5A/CK5BX060 47,000 TDR 12.00 10.60 48,000 3.58 32,400 2.60 8.0
060-30
*FK4DNB006 59,000 TDR&TXV 12.00 10.30 60,000 3.40 39,000 2.46 8.0
CC5A/CD5AA060 55,000 NONE 11.00 9.45 60,000 2.94 39,000 2.24 7.0
CC5A/CD5AW060 57,000 NONE 11.40 9.75 60,000 3.08 38,500 2.30 7.4
CE3AA060 57,000 NONE 11.50 9.75 60,000 3.12 39,000 2.32 7.4
CK3BA060 55,000 NONE 11.00 9.65 60,000 3.06 39,000 2.30 7.0
CK5A/CK5BA060 55,000 NONE 11.00 9.65 60,000 3.06 39,000 2.30 7.0
CK5A/CK5BT060 55,000 NONE 11.00 9.65 60,000 3.06 39,000 2.30 7.0
CK5A/CK5BX060 57,000 NONE 11.50 9.85 60,000 3.18 39,000 2.36 7.4
F(A,B)4BN(F,B,C)060 56,500 TDR 11.00 11.00 9.50 60,000 3.22 39,500 2.36 7.5
F(A,B)4BN(F,B,C)060 56,500 TDR 11.20 9.50 60,000 3.16 40,000 2.32 7.5
FB4BNB070 58,000 TDR 11.50 9.80 60,000 3.30 39,500 2.38 7.7
FC4CN(F,B)060 56,500 TDR&TXV 11.20 9.50 60,000 3.16 40,000 2.32 7.5
FC4CNB070 58,000 TDR&TXV 11.50 9.80 60,000 3.30 39,500 2.38 7.7
FG3AAA060 55,500 NONE 11.30 9.60 60,000 3.04 39,000 2.30 7.3
COILS + 58CV(A,X)110-22 VARIABLE-SPEED FURNACE
CC5A/CD5AA060 54,500 TDR 11.30 9.75 60,000 2.96 38,500 2.28 7.2
CE3AA060 56,500 TDR 11.50 10.05 60,000 3.16 38,500 2.38 7.5
CK3BA060 54,500 TDR 11.50 9.90 60,000 3.28 39,000 2.40 7.5
CK5A/CK5BA060 54,500 TDR 11.50 9.90 60,000 3.28 39,000 2.40 7.5
CK5A/CK5BT060 54,500 TDR 11.50 9.90 60,000 3.28 39,000 2.40 7.5
CK5A/CK5BX060 56,500 TDR 12.00 10.20 60,000 3.30 38,500 2.44 7.5
COILS + 58CV(A,X)135-22 VARIABLE-SPEED FURNACE
CC5A/CD5AA060 54,500 TDR 11.30 9.70 60,000 2.96 38,500 2.28 7.2
CC5A/CD5AW060 54,500 TDR 11.50 10.00 60,000 3.14 38,500 2.36 7.5
CE3AA060 56,500 TDR 11.50 10.05 60,000 3.16 38,500 2.38 7.5
CK3BA060 54,500 TDR 11.50 9.85 60,000 3.28 39,000 2.40 7.5
CK5A/CK5BA060 54,500 TDR 11.50 9.85 60,000 3.28 39,000 2.40 7.5
CK5A/CK5BT060 54,500 TDR 11.50 9.85 60,000 3.28 39,000 2.40 7.5
CK5A/CK5BX060 56,500 TDR 12.00 10.20 60,000 3.30 38,500 2.44 7.5
COILS + 58CV(A,X)155-22 VARIABLE-SPEED FURNACE
CC5A/CD5AA060 54,500 TDR 11.50 9.80 60,000 2.98 38,500 2.28 7.2
CC5A/CD5AW060 54,500 TDR 11.50 10.10 60,000 3.16 38,500 2.36 7.5
CE3AA060 56,500 TDR 11.50 10.10 60,000 3.18 38,500 2.38 7.5
CK3BA060 54,500 TDR 11.50 9.95 60,000 3.28 38,500 2.42 7.5
CK5A/CK5BA060 54,500 TDR 11.50 9.95 60,000 3.28 38,500 2.42 7.5
CK5A/CK5BT060 54,500 TDR 11.50 9.95 60,000 3.28 38,500 2.42 7.5
CK5A/CK5BX060 56,500 TDR 12.00 10.25 60,000 3.30 38,500 2.44 7.5
UNIT
SIZE-
SERIES
INDOOR
UNIT
ARI STANDARD RATINGS*
Cooling Heating
TC
Seasonal Efficiency SEER
EER
High-Temp Low-Temp
Seasonal
Efficiency
HSPF
Factory-
Supplied
Enhance-
ment
Standard
Rating
Field-Supplied
Accessory
TXV**
TXV & TDR**
TC COP TC COP
* Ratings are net values reflecting the effects of circulating fan heat. Supplemental electric heat is not included. Ratings are based on:
Cooling Standard:80°F (27°C) db 67°F (19°C) wb indoor entering air temperature and 95°F (35°C) db air entering outdoor unit.
High-Temperature Heating Standard:70°F (21°C) db indoor entering air temperature and 47°F (8°C) db 43°F (6°C) wb air entering outdoor unit.
Low-Temperature Heating Standard:70°F (21°C) db indoor entering air temperature and 17°F (–8°C) db 15°F (11°C) wb air entering outdoor
unit.
Outdoor section/indoor section combination tested in accordance with DOE test procedures for heat pumps. Ratings for other combinations are
determined under DOE computer simulation procedures.
Requires hard shutoff TXV; based on computer simulation.
** TDR is provided on most Carrier Furnaces.
COP — Coefficient of Performance
HSPF — Heating Seasonal Performance Factor
SEER — Seasonal Energy Efficiency Ratio
TC — Total Capacity (Btuh)
TDR — Time-Delay Relay
TXV — Thermostatic Expansion Valve