– 3 –
1. SPECIFICATIONS
MODEL
42CJR024-723 / 38CJR024-723 42TAR024X-723 / 38TAR024X-723
ITEM Cooling
Capacity
kW
220V 240V 220V
6.40 6.45 6.40
Phase 1
Power source V 220 – 240 220
Hz 50
Power consumption W 2420 2510 2250
Power factor % 98 92 95
220V 240V 220V
R unning current A
0.3/10.9 0.3/11.1 0.3/10.5
Indoor/Outdoor
Starting current A 67
Moisture removal lit/h 2.7
Noise
Indoor (H/M/L) dB 45/41/37
Outdoor (220 – 240V) dB 56-57 56
Refrigerant
Name of refrigerant R22
Rated amount kg 1.70
Refrigerant control Capillary tube
Gas side size mm 15.88
Connection type Flare connection
Liquid side size mm 6.35
Interconnection Connection type Flare connection
pipe Maximum length
m
15*
1
(One way) 25*
2
Maximum height
m10
difference
INDOOR UNIT 42CJR024-723 42TAR024X-723
Height mm 298
Dimensions Width mm 998
Depth mm 208
Net weight kg 13
Evaporator type Finned tube
Indoor fan type Cross flow fan
High fan m
3
/h 900
Air volume Medium fan m
3
/h 750
Low fan m
3
/h 625
Fan motor output W 30
Air filter Honeycomb woven filter with PP frame
OUTDOOR UNIT 38CJR024-723 38TAR024X-723
Height mm 690
Dimensions Width mm 880
Depth mm 310
Net weight kg 58
Condenser type Finned tube
Outdoor fan type Propeller fan
Airflow volume m
3
/h 3380 3560 3380
Fan motor output W 65
Compressor
Model PH400X3CS-4KT1
Output W 1800
Safety device IOL
Louver type Automatic louver
Usable outdoor temperature range °C 21 ~ 43
FILE NO. SVM-05010
Note
*1 Chargeless pipe
*2 Maximum pipe

Table of Contents