Carrier 38E - Defrost Control Board Troubleshooting Steps

Carrier 38E
20 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
every
30,
50
or
90
minutes
of
operating
time.
Control
board
has
additional
feature
that
allows
unit
to
restart
in
defrost
cycle
if
room
thermostat
is
satisfied
during
defrost.
Troubleshooting
defrost
control
involves
a
series
of
simple
steps
that
indicate
whether
board
is
defective.
NOTE:
Procedure
allows
mechanic
to
check
control
board
and
defrost
thermostat
for
defects.
First,
trouble¬
shoot
to
make
sure
unit
operates
properly
in
heating
and
cooling
modes.
This
ensures
problems
are
not
attributed
to
the
defrost
control
board.
Additional
steps
follow:
1.
Turn
thermostat
to
OFF.
Disconnect
all
power
to
outdoor
unit.
2.
Remove
control
box
cover
for
access
to
electrical
components
and
defrost
control
board.
3.
Disconnect
defrost
thermostat
leads
from
control
board,
connect
to
ohmmeter.
Thermostat
leads
are
the
heavy-gage
black
insulated
wires
connected
to
DFT
and
C
terminals
on
control
board.
Resistance
reading
may
be
0
(indicating
closed
defrost
thermo¬
stat)
or
infinity
(
oo
for
open
thermostat)
depending
on
outdoor
temperature.
4.
Jumper
between
DFT
and
C
terminals
on
control
board
as
shown
in
Fig.
9.
5.
Disconnect
outdoor
fan
motor
lead.
Tape
lead
to
prevent
grounding.
6.
Restart
unit
in
heating,
allowing
frost
to
accumulate
on
outdoor
coil.
7.
After
a
few
minutes
in
heating,
liquid
line
tempera¬
ture
should
drop
below
closing
set
point
of
defrost
thermostat.
Using
ohmmeter,
check
resistance
across
defrost
thermostat
leads.
Resistance
of
0
indicates
defrost
thermostat
is
closed
and
operating
properly.
8.
Remove
protective
cover
from
TP1
and
TP2
speed¬
up
terminals.
Insert
jumper
wire
into
protective
cover,
reinsert
protective
cover
on
speed-up
termi¬
nals.
This
reduces
by
1/4
timing
sequence
of
original
time
(see
Fig.
10).
Since
Fig.
10
shows
timing
cycle
set
at
30
minutes,
unit
initiates
defrost
within
approxi¬
mately
30
seconds;
if
setting
is
at
50
minutes,
within
Fig.
10
Inserting
Jumper
Wire
into
Protective
Cover
50
seconds;
90
minutes,
within
90
seconds.
When
you
hear
reversing
valve
change
position,
remove
protec¬
tive
cover/jumper,
otherwise
control
will
terminate
normal
10-minute
defrost
cycle
in
approximately
10
seconds.
A
CAUTION
Do
not
use
screwdriver
or
other
means
to
short
speed-up
pins.
If
pins
are
accidentally
grounded,
control
board
is
destroyed.
9.
U
n
i
t
is
now
operating
in
defrost
mode.
Using
volt¬
meter,
check
between
R
and
W2
as
shown
in
Fig.
II.
Fig.
11
Checking
Between
R
and
W2
9