38GLP---G / 38GLP---G9
Cooling only split system outdoor units
GB - 1
ENGLISH
For operation and maintenance instructions of this unit as well as installation
instructions of the indoor unit, refer to the relevant manuals
Contents
Page
Dimensions and weight ................................................................................................................. 2
Connections .................................................................................................................................. 2
Minimum clearances ..................................................................................................................... 3
System charge............................................................................................................................... 3
General information....................................................................................................................... 4
Warnings: avoid............................................................................................................................. 5
Refrigerant connections ................................................................................................................ 6/8
Operating limits ............................................................................................................................. 8
Electrical connections ................................................................................................................... 9/10
Electrical data ................................................................................................................................10
Pump down and check the refrigerant charge .............................................................................. 11
Unit maintenance .......................................................................................................................... 12
Troubleshooting and guide for the owner ..................................................................................... 12
Accessories ................................................................................................................................... 12
Installation instructions supplement ............................................................................................. 13/14
ATTENTION INSTALLERS AND SERVICE TECHNICIANS!
AIR CONDITIONER WITH R-410A–QUICK REFERENCE GUIDE
R-410A refrigerant operates at 50%-70% higher pressures than R-22. Be sure that servicing
equipment and replacement components are designed to operate with R-410A.
R-410A refrigerant cylinders are pink.
R-410A refrigerant cylinders have a dip tube which allows liquid to flow out of cylinder in an upright
position.
R-410A systems should be charged with liquid refrigerant. Use a commercial type metering device in the
manifold hose in order to vaporize the liquid refrigerant before it enters in the unit.
LR-410A, as other HFCs, is only compatible with oils selected by the compressor manufacturer.
A vacuum pump is not enough to remove moisture from oil.
POE oils absorb moisture rapidly. Do not expose oil to atmosphere.
Never open system to atmosphere while it is under vacuum.
In case the system should be opened for maintenance, stop the vacuum function with dry nitrogen and
replace the drier filters, if any.
Do not vent R-410A into the atmosphere.
Use only Carrier matching indoor units (Table I).
Unit size Oil type
Quantity Drier already installed on
cc liquid line of the unit
18 - 24 POE 1120 YES
28 - 36 - 48 POE 1250 YES
60 POE 1950 YES
Table I
Cooling Power
Hi-Wall
New
Cassette Console Satellite
only models
supply
Hi-Wall
38GLP018G 42PHQ018 42HMC018 40KMC018 42VMC018 40SMC018
38GLP024G
230V ~ 1pH 50Hz
42PHQ024 42HMC024 40KMC024 42VMC024 40SMC024
38GLP018G9 42PHQ018 42HMC018 40KMC018 42VMC018 40SMC018
38GLP024G9 42PHQ024 42HMC024 40KMC024 42VMC024 40SMC024
38GLP028G9 400V 3N ~ 50Hz 40KMC028 42VMC028 40SMC028
38GLP036G9 40KMC036 42VMC036 40SMC036
38GLP048G9 40KMC048 42VMC048 40SMC048
38GLP060G9 40KMC060 42VMC060 40SMC060