PART6, 15
If AC is off before power off and AC is required to start up now, the compressor will have 1 minute
delay when power on. Other conditions, the compressor will have 3 minutes delay when restarts.
3.10 Ionizer function (optional)
The indoor unit is equipped with Ionizer, which is controlled by the CLEAN AIR button on the remote
controller. When the unit is turned on, press the CLEAN AIR button to activate the function. Press it
again to stop the function. During the time when Ionizer is controlled by remote controller, Ionizer will
be turned off automatically if indoor fan stops running due to malfunctions or anti-cold-wind. When
indoor fan restarts after malfunctions being eliminated and anti-cold-wind being released, Ionizer will
be available again.
3.11 8 Heating(optional)
In heating operation, the preset temperature of the air conditioner can be as lower as 8, which keeps
the room temperature steady at 8 and prevents household things freezing when the house is
unoccupied for a long time in severe cold weather.