PC 40 (Communication Error Between Outdoor Main PCB and IPM Board Diagnosis and Solution)
Description: The main PCB cannot detect the IPM board.
Recommended parts to prepare:
Connection wires
•IPM board
Outdoor main PCB
Electric control box
Troubleshooting and repair:
?
Is there at least one LED in
the IPM board light?
t
h
e IPM
b
oar
d
,
?
Check the signal wire between
the IPM board and the main
board, is it connected properly?
Reconnect and retry.
Does the error still appear?
Re
pl
ace
.
Is t
h
e
?
Replace IPM board. Is the
system running normally?
Replace the electric control box.
No
No
No
No
Yes
Trouble
is reso
l
ve
d
Trouble is resolved
No
Yes
?
Replace outdoor main board .
Is the system running
normally?
No
Yes
Yes