38MGRBQ: Service Manual
Manufacturer reserves the right to change, at any time, specifications and designs without notice and without obligations.
84
5 REACTOR REMOVE THE REACTOR
1. Perform the steps from section 2.
2. Loosen the connector between the IPM and reactor.
3. Remove the reactor’s 2 screws.
4. Remove the reactor.
6 4-WAY VALVE REMOVE THE 4-WAY VALVE
1. Perform the steps from section 2.
2. Extract the refrigerant gas.
3. Remove the electrical parts from section 3.
4. Remove the coil screw.
5. Remove the coil.
6. Detach the welded parts of the 4-way valve and pipe.
7 EXPANSION VALVE REMOVE THE EXPANSION VALVE
1. Perform the steps from sections 1 and 2.
2. Remove the electrical parts (see section 3).
3. Remove the coils.
4. Detach the welded parts of the expansion valves and pipes.
ĸ