3 ELECTRICAL PARTS REMOVE ELECTRICAL PARTS REMARKS
1. Perform the steps from sections 1 and 2.
2. Remove the 4 screws securing the IPM board.
3. Unfasten the reactor connector.
4. Unfasten the compressor connector.
5. Disconnect the following three pieces of connection wires
and connectors between IPM and PCB.
6. Remove the IPM Board
7. Disconnect the connectors and wires connected from the
PCB and other parts.
Connectors:
CN17:T3/T4 temperature sensor (2p/2p,white)
CN7: Discharge temperature sensor (2p,white)
CN15:T2B-A,B,C temperature sensor (2p/2p/2p,white)
CN18/CN19/CN22: Electronic expansion valve A,B,C
(6p/6p/6p,red/red/red)
CN25/CN23/CN20: S-A,S-B,S-C (3p/3p/3p,white/white/
white)
Wires:
CN1/CN2: 4-way valve (blue-blue)
CN5/CN6: Crankcase heating cable (red-red)
CN3:L1-IN (red)
CN4:L2-IN (black)
8. Disconnect the grounding wire (yellow-green) after
removing the handle and the right-rear panel.
9. Remove the PCB board.
PCB BoardIPM Board
CN1(5p,white)
CN14(3p,white)
CN3(red or brown)
CN5(blue)
CN1/CN 2
CN
3
CN5/CN 6
CN4
CN20
CN23
CN25