Factory-Installed
Options
Any
condensing
unit
or
heat
pump
listed
in
Tables
1
and
2
may
be
ordered
as
Basic
or
in
one
of
3
factory-option
packages.
Package
designations
are
included
in
model
number
(excluding
Basic).
Example:
38EN024301SA/.
SM
designates
this
unit
as
sheet
metal
option
package.
Option
package
designations
are
shown
in
Table
3.
Table
3
Option
Packages
Basic
38EH,ES
Standard
unit
with
no
added
options.
Sheet
Metal
Option
(SM)
Same
unit
as
Basic
except
with
addition
of
louvered
inlet
casing.
Deluxe
Option
(DL)
Same
unit
as
(SM)
except
for
addition
of
start
assist
components
on
single¬
phase
units,
crankcase
heater,
high-
and
low-pressure
switches,
and
accumulator.
Custom
Deluxe
Option
(CD)
Same
unit
as
(DL)
except
for
addition
of
sound
shield
around
compressor,
and
Time
Guard
II
device.
Basic
38EN
Standard
unit
with
no
added
options.
Sheet
Metal
Option
(SM)
Same
unit
as
Basic
except
for
addition
of
louvered
inlet
casing.
Basic
38QH,QS
Standard
unit
with
no
added
options.
Sheet
Metal
Option
(SM)
Same
unit
as
Basic
except
for
addition
of
louvered
inlet
casing.
Deluxe
Option
(DL)
Same
unit
as
(SM)
except
for
addition
of
start
assist
components
on
single¬
phase
units,
high-pressu.re
switch,
and
Service
Sentry
device.
Custom
Deluxe
Option
(CD)
Same
unit
as
-(DL)
except
for
addition
of
sound
shield
around
compressor
and
Time
Guard
II
device.
Basic
38QN
Standard
unit
with
no
added
options.
Sheet
Metal
Option
(SM)
Same
unit
as
Basic,
except
for
addition
of
louvered
inlet
casing.
Table
4
Condensing
Unit
Specifications
OUTDOOR
UNIT
MODEL
NO.
38-
ORIGINAL
COMPRESSOR
REPLACEMENT
COMPRESSOR
OIL
CHARGE
REFRIG
CHARGE*
MODEL
MODEL
Initial
Recharge
(R-22)
EH-
015301
REZ3-0125
50QT662300
24
20
'
'
6
2
018301
AB5515H
50SR661301
32
30
6.3
024301
MD2315GG
MD2364GE
46
44
5.6
030301
MD3215GG
MD3264GE
46
44
7
3
036301
AV5535E
50SR661336
54
50
7.4
042301
AV5542E
50SR661300
54
50
7.1
048321
AV5546H
50SR661331
54
50
8
9
060301
PC6016BD
PC6066ED
76
72
12.7
EN-
015310
AK8515E
51DZ661300
17
15
3
2
018310
RES3-0175-PFV
38EA662301
24
20
3
7
024310
H21B243ABC
38EN663307
40
37
3
8
030300
H21A313ABCA
38
EN
663302
40
37
5
6
>030320
MD3215GG
MD3264GE
46
44
6
7
036320
H21A363ABCA
38
EN
663303
50
47
5
8'
042300
H21A463ABCA
38EN663304
50
47
7
2
048300
PC5316BD
PC5366HD
76
.
72
7.6
060300
PC6716AG
PC6766HG
76
72
9.6
060310
PC6716AG
PC6766HG
76
72
12.5
030500
H21A313DBD
38EN663501
40
37
5.6
036500
H21A373DBD
38EN663502
50
47
5.8
042500
H21A463DBD
38EN663500
50
47
7.2
048500
PY5316AD
See
Note
t
76
72
7^6
9.6
060500
PY6716AF
See
Note
t
76
72
060510
PY6716AF
See
Note
i
76
72
12.5
036600
H21A373DBE
38
EN
663600
50
47
.
5.8
042600
A21A463DBE
38EN663601
50
47
[
7.2
048600
PH5316AD
PH5366HD
76
72
7
6
060600
PH6716AF
PH6766HF
76
72
9.6
12.5
060610
PH6716AF
PH6766HF
76
72
ES-
018
AB5515H
50SR661301
32
28
7.20
024
CRC1-0175-PFV
38VH660303
55
51
7.40
030
H23A263ABCA
50SR661333
50
46
6.50
036
CRH3-0275-PFV
51HK660304
55
51
7.50
042
CRK3-0325-PFV
48GH
662302
55
51
7.80
048
060
AV5546H
50SR661331
54
50
12.50
Factory
refrigerant
charge
is
adequate
when
indoor
unit
and
outdoor
unit
are
the
same
size
and
are
connected
with
25
ft
or
less
of
field
tubing
of
recommended
size
or
Carrier
accessory
tubing.
For
tubing
requirements
beyond
50ft,
consult
Carrier
distributor.
NOTE:
Originally
an
extended
voltage
compressor.
Select
replacement
compressor
for
voltage
required:
+PF5366HD
(200-3-60),
PG5366HD
(230-3-60).
tPF6766HF
(200-3-60),
PG6766HF
(230-3-60).
H-R
2