16
Heat pump heating performance continued
See notes on pg. 17.
INDOOR
AIR
OUTDOOR COIL ENTERING AIR TEMPERATURES
∞
F
–3 7 17 27 37 47 57 67
Capacity
MBtuh
Total
Power
Capacity
MBtuh
Total
Power
Capacity
MBtuh
Total
Power
Capacity
MBtuh
Total
Power
Capacity
MBtuh
Total
Power
Capacity
MBtuh
Total
Power
Capacity
MBtuh
Total
Power
Capacity
MBtuh
Total
Power
EDB CFM Total Integ† Kw‡ Total Integ† Kw‡ Total Integ† Kw‡ Total Integ† Kw‡ Total Integ† Kw‡ Total Integ† Kw‡ Total Integ† Kw‡ Total Integ† Kw‡
38YCA/YCN042-32, 33, 53, 63 Outdoor Section With F(A,B)4AN(F,B)042 Indoor Section
65
1300
1400
1500
21.7
21.9
22.1
20.0
20.1
20.3
3.51
3.53
3.56
25.4
25.5
25.7
23.3
23.5
23.6
3.57
3.59
3.61
29.1
29.3
29.5
26.5
26.7
26.9
3.62
3.63
3.64
33.1
33.3
33.5
29.4
29.6
29.7
3.67
3.67
3.68
37.4
37.6
37.9
34.0
34.2
34.4
3.75
3.74
3.74
42.2
42.5
42.8
42.2
42.5
42.8
3.85
3.84
3.83
48.4
48.8
49.1
48.4
48.8
49.1
4.03
4.01
3.99
54.5
55.0
55.3
54.5
55.0
55.3
4.24
4.21
4.20
70
1300
1400
1500
21.2
21.5
21.7
19.5
19.7
19.9
3.63
3.65
3.68
25.1
25.3
25.4
23.0
23.2
23.4
3.71
3.72
3.74
28.8
29.0
29.2
26.3
26.4
26.6
3.76
3.77
3.79
32.7
32.9
33.1
29.1
29.3
29.4
3.83
3.83
3.83
37.0
37.2
37.5
33.7
33.9
34.1
3.90
3.89
3.89
41.7
42.0
42.3
41.7
42.0
42.3
4.01
3.99
3.98
47.8
48.1
48.5
47.8
48.1
48.5
4.19
4.17
4.15
53.8
54.2
54.6
53.8
54.2
54.6
4.41
4.38
4.35
75
1300
1400
1500
20.7
20.9
21.1
19.1
19.3
19.5
3.75
3.77
3.80
24.7
24.9
25.1
22.7
22.9
23.1
3.83
3.86
3.88
28.5
28.7
28.9
26.0
26.2
26.3
3.91
3.92
3.93
32.4
32.6
32.8
28.7
28.9
29.1
3.98
3.98
3.98
36.6
36.8
37.1
33.3
33.5
33.7
4.06
4.05
4.05
41.2
41.5
41.8
41.2
41.5
41.8
4.17
4.15
4.15
47.1
47.5
47.8
47.1
47.5
47.8
4.36
4.33
4.32
53.0
53.4
53.8
53.0
53.4
53.8
4.58
4.54
4.52
Multipliers for Determining the Performance With Other Indoor Sections
Indoor
Section Size
Heating
Indoor
Section Size
Heating
Capacity Power Capacity Power
F(A,B)4AN(F,B)
042 1.00 1.00
CC5A/CD5A/CD5BW
042 1.00 1.02
048 1.00 0.96 043 1.00 1.01
FG3AAA
048 1.00 0.98 048 1.00 0.99
CC5A/CD5A/CD5BA
042 1.00 1.01
CD5A/CD5BA
048 1.00 0.99
043 1.00 1.01
CC5A/CD5A/CD5BC
048 1.00 1.04
CD3(A,B)A
042 1.00 1.01
CE3AA
042 1.00 0.99
048 1.00 0.99 048 1.00 0.98
— — —
CF5AA
048 1.00 1.00
38YCA/YCN048-32, 52, 62, 33, 53, 63 Outdoor Section With F(A,B)4AN(F,B)048 Indoor Section
65
1450
1600
1750
21.1
21.3
21.6
19.4
19.6
19.8
3.51
3.55
3.60
25.1
25.4
25.6
23.1
23.3
23.5
3.60
3.63
3.67
29.6
29.9
30.2
27.0
27.3
27.5
3.70
3.72
3.75
34.7
35.0
35.3
30.8
31.1
31.3
3.81
3.82
3.84
40.3
40.7
41.0
36.7
37.0
37.3
3.95
3.95
3.96
47.1
47.6
47.9
47.1
47.6
47.9
4.14
4.14
4.15
55.8
56.3
56.8
55.8
56.3
56.8
4.44
4.43
4.44
64.8
64.4
64.2
64.8
64.4
64.2
4.80
4.69
4.64
70
1450
1600
1750
20.8
21.1
21.3
19.2
19.4
19.6
3.64
3.68
3.72
24.9
25.1
25.3
22.8
23.1
23.3
3.74
3.77
3.80
29.3
29.6
29.9
26.7
27.0
27.2
3.84
3.86
3.89
34.3
34.6
34.9
30.5
30.7
31.0
3.96
3.98
4.00
39.9
40.3
40.5
36.3
36.6
36.9
4.11
4.11
4.12
46.6
47.0
47.4
46.6
47.0
47.4
4.30
4.30
4.30
55.1
55.6
56.1
55.1
55.6
56.1
4.61
4.60
4.60
64.1
64.7
64.0
64.1
64.7
64.0
4.99
4.97
4.85
75
1450
1600
1750
20.5
20.7
21.0
18.8
19.1
19.3
3.76
3.80
3.84
24.6
24.8
25.1
22.6
22.8
23.0
3.88
3.91
3.94
29.0
29.3
29.5
26.5
26.7
26.9
3.99
4.01
4.04
33.9
34.2
34.5
30.1
30.4
30.7
4.12
4.13
4.15
39.5
39.9
40.2
36.0
36.3
36.6
4.28
4.28
4.29
46.0
46.4
46.8
46.0
46.4
46.8
4.48
4.46
4.47
54.4
54.9
55.3
54.4
54.9
55.3
4.79
4.77
4.77
63.2
63.8
64.3
63.2
63.8
64.3
5.17
5.14
5.14
Multipliers for Determining the Performance With Other Indoor Sections
Indoor
Section Size
Heating
Indoor
Section Size
Heating
Capacity Power Capacity Power
F(A,B)4AN(F,B)
048 1.00 1.00
CC5A/CD5A/CD5BC
048 0.98 1.05
060 1.00 0.98
CC5A/CD5A/CD5BW
048 0.99 1.01
FB4ANB
070 1.00 0.95 060 1.00 0.99
FG3AAA
048 1.00 1.01
CC5A/CD5A/CD5BA
060 0.99 1.02
060 1.00 1.00
CE3AA
048 1.00 1.01
CD5A/CD5BA
048 0.99 1.01 060 1.00 0.99
CD3(A,B)A
048 0.99 1.01
CF5AA
048 0.99 1.03
060 0.99 1.02 — — —