EasyManua.ls Logo

Carrier 40MAHBQ36XA3 - DIAGNOSIS AND SOLUTION; EEPROM Parameter Error Diagnosis and Solution (E0;F4)

Carrier 40MAHBQ36XA3
48 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
SG-40MAHB-01: Service Manual
Manufacturer reserves the right to change, at any time, specifications and designs without notice and without obligations.
17
DIAGNOSIS AND SOLUTION
EEPROM Parameter Error Diagnosis and Solution (E0/F4)
Malfunction Decision Conditions
Indoor or outdoor PCB main chip does not receive feedback from the EEPROM chip
Possible Causes:
Installation error
PCB faulty
Troubleshooting
EEPROM: A readonly memory whose contents can be erased and reprogrammed using a pulsed voltage. For the EEPROM chip location,
refer to Fig 21 and Fig. 22.
Fig. 21 — Indoor PCB
Fig. 22 — Outdoor PCB (18K Model)
NOTE:
Figures 21 and 22 are for reference only and may differ from the actual unit.
Yes
Replace the indoor/outdoor
main PCB.
Power off, then restart the
unit 2 minutes later.

Other manuals for Carrier 40MAHBQ36XA3

Related product manuals