2 Outdoor DC Fan Motor (control chip is in the outdoor PCB)
Fig. 39 Outdoor DC Fan Motor
No.
1 2 3 4 5
Color Orange Grey White Pink Black
Signal Hu Hv Hw Vcc GND
Color Red Blue Yellow
Signal W V U
1 Release the UVW connector. Measure the resistance of U- V, U- W, V- W. If the resistance is not equal to each other, the fan motor has
an issue and needs to be replaced. Otherwise, proceed to step 2.
2 Power on and when the unit is in standby, measure the voltage of pin 4 - 5 in the feedback signal connector. If the value is not 5V,
change the PCB. Otherwise proceed to step 3.
3 Rotate the fan by hand, measure the voltage of pin 1- 5, pin 2- 5, and pin 3- 5 in the feedback signal connector. If any voltage is not
positive voltage fluctuation, the fan motor has an issue and must be replaced.