SG-38MHRC-01 Specifications subject to change without notice. 9
CLEARANCES
Fig. 5 — Clearances
Table 6 — Clearances
NOTE: The outdoor unit must be mounted at least 2in. (50mm) above the maximum anticipated snow depth.
Fig. 6 — Clearances for multiple units
UNIT MINIMUM VALUE IN. (MM)
A 24 (609)
B 24 (609)
C 24 (609)
D 4 (101)
E 4 (101)
A
D
B
Air-outlet
Air-inlet
C
E
59in (150cm)
or more when
facing each other
Blowing into the air-inlet of other
condenser shall be avoided.
24in (60cm)
or more
59in (150cm)
or more on a
multiple parallel
unit arrangement
19in (48cm) or more on
a multiple parallel unit
arrangement 4in (10cm)
or more on a single
9.8in (25cm) or more for proper airflow
24in (61cm) or more is recommended
for service