– 17 –
No. Parts name Type Specifications
1 Fan motor (for indoor) AFS-220-31A AC 200 V, 31 W
2 Thermo sensor (TA-sensor) ——— 10 kΩ at 25°C
3 Micro Power Model (M01) µ RW1260 V DC 390 V, Secondary DC 12 V
4 Microcontroller TMP87CM40AN
5 Heat exchanger sensor
——— 10 kΩ at 25°C
(TC-sensor)
6 Line filter (L01) LC*SS11V-06270 27 mH, 600mA
7 Diode (DB01) D3SBA60 4 A, 600 V
8 Capacitor (C63) KMN400VSSN47M22S 4.74µF, 400 V
9 Fuse (F01) BET6.3A T6.3A, 250 V
10 Varistor (R21, R22) 15G561K 560 V
11 Resistor (R319) RF-2TK5R6 5.6 Ω, 2 W
12 Louver motor MP35EA12 Output (Rated) 2 W, 10 poles, 1 phase,
DC 12 V
4. SPECIFICATION OF ELECTRICAL PARTS
4-2. Indoor Unit (42HNR024-713, 42HNR018-713)
FILE NO. SVM-05010
4-1. Indoor Unit (42CJR024-723, 42CJR018-723, 42TAR024X-723, 42TAR018-723)
No. Parts name Type Specifications
1 Fan motor (for indoor) AFS-220-31A AC 200 − 240V, 31W
2 Thermo sensor (TA-sensor) ——— 10 kΩ at 25°C
3 Micro Power Module (M01) µRM1260V DC 390 V, Secondary DC 12 V
4 Microcontroller TMP87CM40AN
5 Heat exchanger sensor
——— 10 kΩ at 25°C
(TC-sensor)
6 Line filter (L01) LC*SS11V-06270 27mH, 600mA
7 Diode (DB01) D3SBA60 4 A, 600 V
8 Capacitor (C63) KMH400VSSN47M22S 4.7µF, 400 V
9 Fuse (F01) BET6.3A T6.3 A, 250 V
10 Varistor (R21, R22) 15G561K 560 V
11 Resistor (R319) RF-2TK5R6 5.6Ω , 2 W
12 Louver motor MP35EA12 Output (Rated) 2 W, 10 poles, 1 phase,
DC 12 V
13 Relay : (RY04) G5NB-1A Coil DC 12V, 16.7mA, Contact AC 250V, 1A