37
ELECTRIC CIRCUIT DIAGRAM
7
1) FUNCTIONAL CIRCUIT DIAGRAM
a 42HWG007/009/012 & HWG195/225/305C-SERIES
• After the power I/O button is pressed once, the Power-relay and AC SWITCH are turned
on or off per the remote control setpoint.
– AC SWITCH U9 is controlled per the fan speed selection.
– Power-relay K1 is controlled per the operation mode selection.
• If the power I/O button is pressed once more, the Power-relay and AC SWITCH are turned
off and the unit stops operation.
• The unit turns on or off according to the temperature setpoint by sensing the room air
temperature through thermistor.
• If the fan speed selection is set to the auto position, the fan speed is automatically con-
trolled according to the temperature difference between room temperature and tempera-
ture setpoint.