4
Model
Function
Power Supply
Capacity
W
Btu/h
L/h
Electrical data A
(ID unit only) W
Electrical data A
(System) W
A
max (*)
W
max (*)
Type
Fan
RPM (Hi/Lo)
Capacitor
Motor Model Number
Connection
Type
OD (Liquid/Suction)
Cord connection conductor size
(Power supplied to
outdoor unit)
Dimension (WxHxD) mm
Net Weight Kg
OD UNIT
42HWG018 / HWG455C
Cooling
230V-1PH-50Hz
4690
16007
1.7
0.19
45
7.9
1780
20
2270
Cross flow fan
1150/950
1.8µF, 450V
IC-9430G4KG7A
Flare
1/4”(6.35) 1/2”(12.7)
R,C,Y: 1.0mm
2
1080x295x185
14
38GL--18---703EC-40
SKY455C
42HWG024 / HWG605C
Cooling
230V-1PH-50Hz
6240
21300
2.5
0.19
45
10.6
2420
17
3300
Cross flow fan
1250/1050
1.8µF, 450V
IC-9430G4KG7A
Flare
1/4”(6.35) 5/8”(15.88)
R,C,Y: 1.0mm
2
1080x295x185
14
38GL--24---703EC-40
SKY605C
NOTE: Cooling capacity test is performed through temperature condition based
on 27ºC D.B., 19ºC W.B., in indoor and 35ºC D.B., 24ºC W.B. in outdoor.
Cooling capacity test is performed at high voltage.
Specification can change without notice.