5
Model
Function
Power Supply
Capacity
W
Btu/h
L/h
Electrical data A
(ID unit only) W
Electrical data A
(System) W
A
max (*)
W
max (*)
Type
Fan
RPM (Hi/Lo)
Capacitor
Motor Model Number
Connection
Type
OD (Liquid/Suction)
Cord connection conductor size
(Power supplied to
outdoor unit)
Dimension (WxHxD) mm
Net Weight Kg
OD UNIT
42HQG018 HWG455H
Cooling Heating
230V-1PH-50Hz
4790 5100
16360 17420
1.7
0.19 0.19
45 45
7.3 6.7
1630 1490
x 8.0
2270 1800
Cross flow fan
1150 950
1.8µF, 450V
IC-9430G4KG7A
Flare
1/4”(6.35) 1/2”(12.7)
R,C,Y,O,W2 : 1.0mm
2
S1, S2 : 0.75mm
2
1080x295x185
14
38YL--18---703EC-40
SKY455HJ
42HQG024 HWG605H
Cooling Heating
230V-1PH-50Hz
6110 7170
20886 24486
2.5
0.19 0.19
45 45
10.7 11
2430 2480
17.0 14.6
3300 2900
Cross flow fan
1250 1050
1.8µF, 450V
IC-9430G4KG7A
Flare
1/4”(6.35) 5/8”(15.88)
R,C,Y,O,W2 : 1.0mm
2
S1, S2 : 0.75mm
2
1080x295x185
14
38YL--24---703EC-40
SKY605HJ
NOTE: Cooling capacity test is performed through temperature condition based
on 27ºC D.B., 19ºC W.B., in indoor and 35ºC D.B., 24ºC W.B. in outdoor.
Cooling capacity test is performed at high voltage.
Specification can change without notice.