EasyManua.ls Logo

Carrier 42QHF012DS - Page 3

Carrier 42QHF012DS
5 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
G B
READ BEFORE INSTALLATION
1.2 Installation Diagram of Indoor and Outdoor Units
Air freshening filter(1) (used to install on Air filter)
6
1.1 Safety Precaution
This product contains fluorinated gases covered by the Kyoto Protocol
Chemical Name of Gas
Global Warming Potential (GWP) of Gas
R410A
2088
CAUTION
1. Paste the enclosed refrigerant label adjacent to the charging and /or
recovering location.
2. Clearly write the charged refrigerant quantity on the refrigerant label
using indelible ink.
3. Prevent emission of the contained fluorinated gas. Ensure that the
fluorinated gas is never vented to the atmosphere during installation,
service or disposal. When any leakage of the contained fluorinated
gas is detected, the leak shall be stopped and repaired as soon as
possible.
4. Only qualified service personnel are allowed to access and service
this product.
5. Any handling of the fluorinated gas in this product, such as when
moving the product or recharging the gas, shall comply under (EC)
Regulation No. 842/2006 on certain fluorinated greenhouse gases
and any relevant local legislation.
6. Contact dealers, installers, etc., for any questions.
Accessories
WARNING
In order to avoid a hazard due to inadvertent resetting of the thermal cut-out, this
appliance must not be supplied through an external switching device, such as a timer,
or connected to a circuit that is regularly switched on and off by the utility..
Electrical work should be carried out in accordance with the installation manual and
the national, state and local electrical wiring codes.
Be sure to use a dedicated power circuit. Never share the same power outlet with
other appliance.
Be sure the unit be grounded properly.
Never modify this unit by removing any of the safety guards or bypassing any of the
safety interlock switches.
When installing or relocating the system, do not allow air or any substances other
than the specified refrigerant (R410A) to enter the refrigeration cycle.
To avoid personal injury, be careful when handling parts with sharp edges.
CAUTION
Do not install the indoor or outdoor units in a location with special environmental
conditions.
Do not install in a place that can amplify the noise level of the unit or where noise and
discharged air might disturb neighbors.
Note: Ensure the spaces indicated by arrows from the wall, ceiling,
fence or other obstacles.
Use the prescribed cables for electrical connection(H07RN-F) with insulation protected
by insulation sleeving having an appropriate temperature rating.

Other manuals for Carrier 42QHF012DS

Related product manuals