EasyManua.ls Logo

Carrier 48HD008 - INSTALLATION - AIR INLET ADJUSTMENTS; Outdoor Air Damper Installation

Carrier 48HD008
26 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
-Factory
Wiring
-Field
Wiring
-RED
-
-BLK-
-BLU
-
-PNK
-
-ORN-
-
VIO-
(48HD,
HH
ONLY)
HDD,
HHD008
-BRN-
-WHT-
Fig.
8
Control
Wiring
Connections
-4
4
-4
H
Fig.
9
Outdoor
Air
Damper
and
Hood
Installation
and
Details
(004,005,006,007
Units)
Route
thermostat
cable
or
equivalent
single
leads
of
colored
wire
from
subbase
terminals
through
con¬
nector
on
unit
to
low-voltage
connections
as
shown
in
Fig.
8.
NOTE:
For
wire
runs
up
to
50
ft,
use
no.
18
AWG
insulated
wire
(35
C
mininum).
For
50
to
75
ft,
use
no.
16
AWG
insulated
wire
(35
C
minimum).
Pass
the
control
wires
through
the
hole
provided
in
the
corner
post;
then
feed
wires
through
the
race¬
way
built
into
the
corner
post
to
the
24-v
barrier
located
on
the
left
side
of
the
control
box.
HEAT
ANTICIPATOR
SETTINGS
Set
heat
anticipator
settings
at
1.20
for
460-volt
units
and
1.00
for
208/
230-volt
units.
Settings
may
be
changed
slightly
to
provide
a
greater
degree
of
comfort
for
a
particular
installation.
Step
8
Make
Outdoor
Air
Inlet
Adjustments
and
Install
Outdoor
Air
Hood
OPTIONAL
OUTDOOR
AIR
DAMPER
48HDT,LDT004,005,006
and
HD007
Optional
outdoor
air
damper
is
shipped
with
hood
broken
down
inside
of
unit.
See
Fig.
9.
Assembly
1.
Remove
filter
access
panel.
2.
Remove
sheet
metal
parts
from
filter
area.
3.
Using
screws
provided,
assemble
sides
to
the
inside
of
the
hood.
See
Fig.
9.
4.
Discard
baffle.
5.
Install
damper
blade
by
inserting
threaded
pins
through
hole
in
side
plates.
6.
Use
wing
nuts
provided
to
hold
blade
in
place.
7.
Install
outdoor
air
hood
assembly,
using
screws
provided.
8.
Install
outdoor
air
inlet
screen
and
screen
retainer.
9.
Replace
access
panel.
Fig.
10
Access
Panel
Location
(008
Units)
10.
L
o
osen
wing
nut
on
side
plate
to
adjust
blade.
Adjust
damper
blade
to
desired
setting
for
out¬
side
air
intake.
48HD,LD/
HDD,LDD008
Optional
outdoor
air
damper
is
shipped
with
hood
broken
down
in
unit
filter
section.
See
Fig.
10.
Assembly
1.
Remove
protective
cover
from
unit.
See
Fig.
10.
2.
Remove
upper
filter
access
panel
(save
screws).
See
Fig.
10.
3.
Remove
hood
parts
from
unit
evaporator
fan
and
filter
area.
Assemble
hood
top
and
side
plates
as
shown
in
Fig.
11.
Do
not
attach
hood
to
unit
at
this
time.
4.
Adjust
outdoor
air
damper
blade
to
desired
setting
for
outside
air
intake
by
releasing
linkage
rod
setscrew
and
adjusting
linkage
rod.
See
Fig.
12.
Secure
damper
blade
in
desired
position
with
setscrew.
5.
Remove
screws
holding
manual
outdoor
air
damper
to
unit.
See
Fig.
13.
10

Related product manuals