Carrier 48HD008 - INSTALLATION - FAN SPEED ADJUSTMENT; Evaporator Fan Speed Adjustment; START-UP PROCEDURES; Unit Preparation and Checks

Carrier 48HD008
26 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
f
PINK
PINK
CLS
4
t-
RED
Ec
SEE
NOTE
I
©°"TfQ(D"
1
I
I
__
OAT
_
I
BLUE
4
CLS
Cooling
Lockout
Switch
EC
Enthalpy
Control
OAT.
Outdoor
Air
Thermostat
NOTE:
When
enthalpy
control
(EC)
is
installed,
outdoor
air
thermo¬
stat
(OAT
)
is
removed
from
economizer
Fig.
30
Wiring
Connections
for
Outdoor
Air
Thermostat/or
Enthalpy
Control
and
Cooling
Lockout
Switch
(008
Units)
Fig.
31
Indoor
Air
Fan
Pulley
Adjustment
Step'
9
Adjust
Evaporator
Fan
Speed
On
48HDT,LDT004,005,006
and
48LH006
units,
the
evaporator
fan
motor
factory
speed
setting
is
shown
on
label
diagram
affixed
to
base
unit.
If
other
than
factory
setting
is
desired,
refer
to
label
diagram
for
motor
reconnection.
On
48H
H006
and
all
007
and
008
units,
fan
motor
pulleys
are
factory
set
for
speed
shown
in
Table
1.
To
change
fan
speeds:
1.
Shut
off
unit
power
supply.
2.
Loosen
belt
by
loosening
fan
motor
mounting
plate
nuts.
3.
Loosen
movable
pulley
flange
setscrew
(see
Fig.
31).
4.
Screw
movable
flange
toward
fixed
flange
to
in¬
crease
speed
and
away
from
fixed
flange
to
decrease
speed.
Increasing
fan
speed
increases
load
on
motor.
Do
not
exceed
maximum
speed
specified
in
Table
1.
5.
Set
movable
flange
at
nearest
key
way
of
pulley
hub
and
tighten
setscrew.
(See
Table
1
for
speed
change
for
each
full
turn
of
pulley
flange.)
To
align
fan
and
motor
pulleys,
loosen
fan
pulley
setscrews
and
slide
fan
pulley
along
fan
shaft.
Make
angular
alignment
by
loosening
motor
from
mount¬
ing
plate.
To
Adjust
Belt
Tension
Loosen
fan
motor
pivot
bolts.
Move
motor
mounting
plate
up
or
down
for
proper
belt
tension
(1/2-in.
deflection
with
one
finger)
and
tighten
pivot
bolts.
Adjust
lock
bolt
and
nut
on
mounting
plate
to
secure
in
fixed
position.
START-UP
Unit
Preparation
Make
sure
that
unit
has
been
installed
in
accordance
with
installation
instructions
and
applicable
codes.
Return
Air
Filters
Make
sure
correct
filters
are
installed
in
filter
tracks.
See
Table
1.
Do
not
operate
unit
without
return
air
filters.
Outdoor
Air
Inlet
Screens
Outdoor
air
inlet
screen(s)
must
be
in
place
before
operating
unit.
Compressor
Mounting
Compressors
are
inter¬
nally
spring
mounted.
Do
not
loosen
or
remove
compressor
holddown
bolts.
Internal
Wiring
Check
all
electrical
connections
in
unit
control
boxes.
Tighten
as
required.
Refrigerant
Service
Valves
Each
unit
system
has
2
Schrader
type
service
ports,
one
on
the
suction
line
and
one
on
the
compressor
discharge
line.
Be
*
sure
that
caps
on
the
ports
are
tight.
Cooling
To
start
unit,
turn
on
main
power
supply.
Set
system
selector
switch
at
COOL
and
fan
switch
at
AUTO.
Adjust
thermostat
to
a
setting
below
room
temperature.
Compressor
starts
on
closure
of
contactor.
Check
cooling
effects
at
a
setting
above
room
temperature.
Check
unit
charge.
Refer
to
Refrig¬
erant
Charge
in
Service
section.
Reset
thermostat
at
a
position
above
room
tem¬
perature.
Compressor
will
shut
off.
TO
SHUT
OFF
UNIT
Set
system
selector
switch
at
OFF
position
or
reset
thermostat
at
a
position
above
room
temperature.
Units
are
equipped
with
Signal-LOC
protection
device.
Unit
shuts
down
on
16