17
Table 11 – PHYSICAL DATA (HEATING) 7.5 -- 10 TONS
48TC**08 48TC* *09 48TC**12
Gas Connection
#ofGasValves 1 1 1
Nat. gas supply line press (in. w.g.)/ (PSIG) 4 --- 1 3 / 0 . 1 8 --- 0 . 4 7 4 --- 1 3 / 0 . 1 8 --- 0 . 4 7 4 --- 1 3 / 0 . 1 8 --- 0 . 4 7
LP supply line press (in. w.g.) / (PSIG) 11 --- 13 / 0.40 --- 0.47 11 ---13 / 0.40 --- 0.47 11 --- 13 / 0.40 --- 0.47
Heat Anticipator setting (Amps)
1st stage 0.14 0.14 0.14
2nd stage 0.14 0.14 0.14
Natural Gas Heat
LOW
#ofstages/#ofburners(total)
1/3 1/3 2/4
Connection Size
1 / 2 --- i n N P T 1 / 2 --- i n N P T 3 / 4 --- i n N P T
Rollout switch opens / closes
195 / 115 195 / 115 195 / 115
Tem pe r at ur e R is e
20 --- 50 20 --- 50 25 --- 65
MED
#ofstages/#ofburners(total)
2/4 2/4 2/5
Connection Size
3 / 4 --- i n N P T 3 / 4 --- i n N P T 3 / 4 --- i n N P T
Rollout switch opens / closes
195 / 115 195 / 115 195 / 115
Tem pe r at ur e R is e
35 --- 65 30 --- 65 30 --- 65
HIGH
#ofstages/#ofburners(total)
2/5 2/5 2/5
Connection Size
3 / 4 --- i n N P T 3 / 4 --- i n N P T 3 / 4 --- i n N P T
Rollout switch opens / closes
195 / 115 195 / 115 195 / 115
Tem pe r at ur e R is e
45 --- 75 40 --- 75 35 --- 70
Liquid Propane Heat
LOW
#ofstages/#ofburners(total)
1/3 1/3 2/4
Connection Size
1 / 2 --- i n N P T 1 / 2 --- i n N P T 3 / 4 --- i n N P T
Rollout switch opens / closes
195 / 115 195 / 115 195 / 115
Tem pe r at ur e R is e
20 --- 50 20 --- 50 25 --- 65
MED
#ofstages/#ofburners(total)
2/4 2/4 2/5
Connection Size
3 / 4 --- i n N P T 3 / 4 --- i n N P T 3 / 4 --- i n N P T
Rollout switch opens / closes
195 / 115 195 / 115 195 / 115
Tem pe r at ur e R is e
35 --- 65 30 --- 65 30 --- 65
HIGH
#ofstages/#ofburners(total)
2/5 2/5 2/5
Connection Size
3 / 4 --- i n N P T 3 / 4 --- i n N P T 3 / 4 --- i n N P T
Rollout switch opens / closes
195 / 115 195 / 115 195 / 115
Tem pe r at ur e R is e
45 --- 75 40 --- 75 35 --- 70
Low NOx Gas Heat
LOW
#ofstages/#ofburners(total)
--- --- ---
Connection Size
--- --- ---
Rollout switch opens / closes
--- --- ---
Tem pe r at ur e R is e
--- --- ---
MED
#ofstages/#ofburners(total)
--- --- ---
Connection Size
--- --- ---
Rollout switch opens / closes
--- --- ---
Tem pe r at ur e R is e
--- --- ---
HIGH
#ofstages/#ofburners(total)
--- --- ---
Connection Size
--- --- ---
Rollout switch opens / closes
--- --- ---
Tem pe r at ur e R is e
--- --- ---
--- N o t a p p l i c a b l e