2 - USER INTERFACES
2.1. Graphic terminal (standard)
Keys and combinations (quick guide)Features
LCD FSTN display (132 x 64 pixel), backlit in blue.
The screen provides detailed explanations of control in easy to
understand English. No decoding is required.
Only 6, large, easy-to-use buttons are required to maneuver
through the entire menus.
Dimensions:
156 mm (Length) x 82 mm (Width) x 31 mm (Depth)
First run of the software
On the rst run of the software installed on the control, the following
screen appears on the terminal, informing about the installation of
the values by default:
When you switch on the power again, the terminal loads the initial
screen, showing:
The unit number in a shared network (U01 corresponds to the unit
con gured as "Master" of the network or a stand-alone unit).
The measured indoor temperature (Ind.T).
The measured outdoor temperature (Out.T).
The default installation language. The available languages are:
Spanish (ES), French (FR), English (EN) and Italian (IT).
The time and date.
U01 Ind.T: 00.0ßC
Out.T: 00.0ßC
00:00 EN 00/00/00
When loaded the screen will look like this:
Loading....
Key Function
Alarm There is/are active alarm(s) if the key is illuminated
red.
By pressing the key once, the description of the
rst alarm will be shown. By using the up/down
keys, the other alarms stored in the memory can be
consulted. By pressing this key for a second time,
the alarm(s) will be reset.
If no alarm is active, the message “No alarm active"
appears.
Prg This key allows access to the MAIN MENU. All
the screens of this control can be selected from
this menu.
The key will light up in orange.
Esc To exit any screen, pressing this key returns the
user to the start screen of the previous menu.
From the initial screen, if keeping this key pressed
for a few seconds, access is given to a group of
help screens with information on the key or key
combination that enable performing the most
important control functions.
Esc
+
Down
By pressing both keys simultaneously, it’s possible
to change of unit in the pLAN network (shared
graphic terminal).
Up
Down
These keys enable consulting the information
displayed on-screen by going forward or back.
They can also modify values.
By pressing both keys at the same time, direct
access is gained to the group of screens “06. Input/
Output” (belonging to the MAIN MENU).
Enter This enables con rming the modi ed values.
By pressing the key once, the cursor is placed on
the rst screen parameter.
Pressing the key again confirms the adjusted
parameter value and it then proceeds to the next
parameter.
Prg
+
Enter
The unit is switched on or switched o󰀨 by pressing
both these keys at the same time for a few seconds.
This action is equivalent to the On/O󰀨 from the
screen “02. Unit On/O󰀨 ” (belonging to the MAIN
MENU).
Prg
+
Up
HEATING mode (winter) is selected by pressing
both these keys at the same time for a few seconds.
Prg
+
Down
COOLING mode (summer) is selected by pressing
both these keys at the same time for a few seconds
Alarm
+
Down
The language of the screens is selected by pressing
both these keys at the same time for a few seconds