PERFORMANCE DATA (CONT)
COOLING E XTENDED PERFORMANCE TABLE
50SZ042
TEMP °F(°C)
OUTDOOR AIR
ENTERING
CONDENSER
EVAPORATOR AIR --- CFM/BF
1225 / 0.11 1400 / 0.12 1575 / 0.14
Evaporator Air Ewb °F(°C)
57
(13.8)
62
(16.6)
63*
(17.2)
67
(19.4)
72
(22.2)
57
(13.8)
62
(16.6)
63*
(17.2)
67
(19.4)
72
(22.2)
57
(13.8)
62
(16.6)
63*
(17.2)
67
(19.4)
72
(22.2)
75
(23.8)
TC 36.8 40.2 41.7 42.5 45.4 38.2 41.8 41.1 45.3 45.5 39.3 40.7 41.1 44.4 46.3
SHC 36.8 38.5 28.5 28.5 21.8 38.2 40.0 29.8 31.5 23.0 39.3 37.4 31.0 32.2 24.1
kW 3.1 3.3 3.3 3.2 3.6 3.2 3.3 3.3 3.3 3.3 3.3 3.4 3.5 3.4 3.4
85
(29.4)
TC 35.4 38.1 40.0 41.4 44.3 36.8 38.9 40.5 42.1 44.8 38.0 40.2 40.9 43.8 45.2
SHC 35.4 36.4 27.7 28.2 22.0 36.8 38.3 29.6 30.2 23.4 38.0 39.5 31.6 32.8 24.9
kW 3.5 3.4 3.4 3.4 3.6 3.6 3.5 3.5 3.6 3.5 3.7 3.6 3.6 3.6 3.6
95
(35)
TC 34.1 37.2 38.0 40.8 43.8 35.4 38.6 38.8 41.5 44.0 36.5 39.6 37.9 42.0 44.4
SHC 34.1 35.5 26.9 27.9 21.9 35.4 36.9 28.9 30.0 23.0 36.5 37.8 30.0 32.1 24.2
kW 3.9 3.7 3.7 3.7 3.7 4.0 3.8 3.8 3.8 3.8 4.1 3.8 3.8 3.9 3.9
105
(40.5)
TC 32.4 35.1 35.6 38.2 40.7 33.7 36.5 36.2 38.8 41.2 34.7 35.4 34.7 37.4 41.4
SHC 32.4 33.6 25.8 26.9 20.8 33.7 34.9 27.8 29.0 21.8 34.7 33.8 28.5 29.8 22.3
kW 4.0 4.0 4.0 4.0 4.0 4.1 4.0 4.0 4.1 4.1 4.2 4.1 4.1 4.1 4.2
115
(46.6)
TC 30.1 33.4 33.5 36.1 37.3 31.3 32.9 32.4 35.0 39.0 32.3 33.9 31.6 34.0 38.0
SHC 30.1 31.9 25.0 26.0 18.9 31.3 31.5 26.2 27.3 21.3 32.3 32.4 30.2 32.5 22.1
kW 4.4 4.3 4.3 4.4 4.3 4.5 4.7 4.4 4.4 4.5 4.6 4.8 4.8 4.8 4.9
125
(51.6)
TC 27.9 29.6 28.4 32.4 34.2 32.2 29.9 28.6 31.2 34.1 29.7 30.8 29.0 31.7 34.1
SHC 27.9 28.3 24.3 24.7 19.2 18.9 28.6 24.5 25.7 19.1 29.7 29.4 26.7 27.5 17.8
kW 4.8 4.9 4.9 4.8 5.1 5.0 4.7 4.7 4.8 5.1 5.2 4.9 4.8 4.8 4.9
Seepage16forcoolingnotes.
HEATING EXTENDED PERFORMANCE TABLE
50SZ042
RE-
TURN
AIR
°Fdb
(°C)
CFM
(Standard
Air)
AIR TEMPERATURE ENTERING OUTDOOR COIL °F(°C)
-- 1 0
(--23.3)
0
(--17.7)
10
(--12.2)
17
(--8.3)
20
(--6.6)
30
(--1.1)
40
(4.4)
47
(8.3)
50
(10)
60
(15.5)
60
(15.5)
1225
TC 13.8 12.8 17.1 15.7 20.5 18.8 23.1 21.1 24.7 22.4 30.4 26.7 37.1 37.1 39.7 39.7 41.6 41.6 48.2 48.2
kW 2.50 2.63 2.76 2.85 2.91 3.11 3.29 3.44 3.51 3.75
1400
TC 13.9 12.8 17.2 15.8 20.6 18.9 23.3 21.3 24.9 22.6 30.6 26.8 37.2 37.2 40.0 40.0 41.9 41.9 48.2 48.2
kW 2.48 2.60 2.72 2.81 2.86 3.03 3.23 3.34 3.40 3.62
1575
TC 14.0 12.9 16.8 15.5 20.6 19.0 23.4 21.4 25.0 22.7 30.8 27.0 35.3 35.3 40.1 40.1 41.9 41.9 48.1 48.1
kW 2.46 2.58 2.68 2.77 2.82 2.97 3.13 3.27 3.31 3.52
70
(21.1)
1225
TC 13.1 12.1 16.5 15.2 20.1 18.5 22.7 20.7 24.2 22.0 29.8 26.1 36.2 36.2 41.3 41.3 43.2 43.2 47.6 47.6
kW 2.64 2.83 2.99 3.09 3.15 3.38 3.61 3.79 3.87 4.07
1400
TC 13.2 12.2 16.6 15.3 20.2 18.6 22.8 20.8 24.3 22.1 29.9 26.2 36.5 36.5 41.5 41.5 41.1 41.1 47.7 47.7
kW 2.63 2.79 2.94 3.04 3.10 3.30 3.49 3.69 3.69 3.93
1575
TC 13.3 12.3 16.7 15.4 20.3 18.6 22.9 20.9 24.4 22.2 30.1 26.4 36.6 36.6 39.4 39.4 41.3 41.3 47.6 47.6
kW 2.61 2.77 2.91 3.00 3.05 3.23 3.43 3.55 3.61 3.83
80
(26.6)
1225
TC 12.0 11.1 15.8 14.5 19.6 18.0 22.4 20.4 23.8 21.6 29.2 25.6 35.5 35.5 40.5 40.5 42.4 42.4 46.8 46.8
kW 2.74 3.01 3.22 3.36 3.42 3.67 3.93 4.13 4.20 4.43
1400
TC 12.1 11.2 15.9 14.7 19.0 17.4 22.4 20.5 23.9 21.6 29.4 25.7 35.7 35.7 40.7 40.7 42.7 42.7 47.0 47.0
kW 2.73 2.99 3.18 3.30 3.36 3.59 3.82 4.00 4.08 4.27
1575
TC 12.3 11.3 16.1 14.8 19.9 18.2 22.5 20.5 23.9 21.7 29.5 25.8 35.9 35.9 41.4 41.4 43.5 43.5 47.6 47.6
kW 2.73 2.96 3.15 3.26 3.31 3.53 3.74 3.86 3.89 4.07
LEGEND
Cap. — Heating Capacity (1000 Btuh) (Includes Indoor---Fan Motor
Heat)
db —DryBulb
kW — Total Power Input (Includes Compressor Motor Power Input
Outdoor---Fan Motor Input, and Indoor---Fan Motor Input)
rh — Relative Humidity
NOTES:
1. indicates integrated ratings
2. Integrated capacity is maximum (instantaneous) capacity less the effect
of frost on the outdoor coil and the heat required to defrost it.