40
CONNECTING ELECTRICAL WIRING (Cont.)
18-3 ELECTRICAL DATA
Split
System
Model
Starting
Current
(Note 1)
Nominal
System
Power
Supply
Electrical Consumption
Circuit
Breaker
Cooling
Heating
****
35 °C
*
46 °C
**
52 °C
***
Heat Pump Amp V/1Ph/50Hz Amp Watt Amp Watt Amp Watt Amp Watt Amp
53QHET30 91 220-240 15.3 3250 18.4 3787 20.1 4080 12.8 2766 32
53QHET36 115 220-240 21.1 4158 25.1 4807 27.3 5247 17.2 3114 40
53QHE36 86 220-240 18 3889 21.1 4531 - - 14 3114 40
Cool Only Amp V/1Ph/50Hz Amp Watt Amp Watt Amp Watt Amp Watt Amp
53KHET30 91 220-240 15.0 3242 17.9 3777 19.5 4069 32
53KHET36 115 220-240 21.0 4138 24.9 4820 27.0 5192 40
NOTES
1. Starting Current duration is usually less than 1 Second.
2. Operating Conditions.
* @ 35ºC db outdoor temperature :
27/19ºC db/wb Indoor Temperature. High air flow of indoor unit
** @ 46ºC db outdoor temperature :
29/19ºC db/wb Indoor Temperature. High air flow of indoor unit
*** @ 52ºC db outdoor temperature :
32/23ºC db/wb Indoor Temperature. High air flow of indoor unit
**** Standard operating conditions for heating
Indoor 20 °C DBT Outdoor 7/6 °C DBT/WBT High speed of indoor unit